ABB Pulse Encoder Interface Module | NTAC-02 | 58976008 | for ACS600/ACS800 Drives
1. Product Overview
The ABB NTAC-02 (order number 58976008) is a Pulse Encoder Interface Module manufactured by ABB Drives, specifically designed for ABB ACS600 and ACS800 series industrial drives. It is used to connect incremental pulse encoder speed and position feedback signals to the drive, enabling high-precision closed-loop speed control and position control, widely used in industrial applications requiring precise speed regulation, positioning, and synchronization control.
In industrial drive applications, when precise speed or position (angle) feedback from the motor shaft is required, a pulse encoder must be used. The pulse encoder is mounted on the motor shaft and outputs A-phase, B-phase quadrature pulse signals and Z-phase zero pulse signals as the motor rotates. The NTAC-02 pulse encoder interface module serves as a bridge between the encoder and the drive, receiving the pulse signals output by the encoder, performing signal conditioning, electrical isolation, and counting processing, then transmitting speed and position data to the drive main control unit via the drive internal bus. This enables the drive to implement advanced control functions such as closed-loop vector control, Direct Torque Control (DTC), speed closed-loop regulation, position positioning control, and multi-axis synchronization control.
The NTAC-02 supports incremental pulse encoder input, including A-phase, B-phase quadrature pulse signals, and optional Z-phase (zero/index) pulse signals. The A/B-phase quadrature signals can determine rotation direction (forward/reverse) through phase difference, calculate rotation angle and position through pulse counting, and calculate rotation speed through pulse frequency. The Z-phase zero pulse outputs one pulse per revolution for position homing and reference point positioning. The maximum input signal frequency is as high as 100 kHz, meeting the precise speed feedback requirements of high-speed rotating motors, providing sufficient pulse resolution and response speed even at the motor's maximum speed.
In terms of signal levels, the NTAC-02 supports HTL (Push-Pull) and TTL level encoder signal inputs. The HTL level signal high-level threshold is greater than 7.6V, and the low-level threshold is less than the specified value (specific subject to official manual), with strong anti-interference capability and long transmission distance, suitable for long-distance encoder signal transmission in industrial fields. TTL level signals are suitable for short-distance, high-rate signal transmission. The module has built-in signal conditioning and shaping circuits that can filter, shape, and level-convert encoder input signals, ensuring stable and reliable reception of encoder signals in complex industrial electromagnetic environments.
The NTAC-02 provides encoder power supply output, with 15V or 24V DC voltage selectable via jumper to power the external encoder, eliminating the need for an additional encoder power supply and simplifying system wiring and configuration. The encoder power output has short-circuit protection and overcurrent protection to prevent module damage caused by encoder wiring short circuits or faults. The module itself uses 24V DC industrial standard power supply (voltage range 24V DC ±10%), with power consumption of approximately 7.5W (300mA), and can be directly powered by the drive internal or external 24V DC control power supply.
In terms of electrical isolation, the NTAC-02 provides electrical isolation between the encoder input signals and the drive internal control circuit, effectively protecting the drive's sensitive control electronics from electrical noise, common-mode voltages, and transient overvoltages generated by the motor and encoder cables, while reducing ground loop interference and improving system anti-interference capability and operational reliability. Electrical isolation is an important safety feature for industrial encoder interfaces, especially in high-power drive applications where high shaft voltages may be induced on the motor shaft and coupled through encoder cables to the encoder and interface circuits. Electrical isolation can effectively block this coupling.
The NTAC-02 features a plug-in/rail-mount module design, installed in the drive's option slot or on a DIN rail in the control cabinet (specific mounting method subject to official manual), communicating with the drive main control unit via the drive internal bus or dedicated connector. The module has compact dimensions (approximately 108mm × 75mm × 45mm, net weight approximately 0.5kg), saving installation space. Onboard status indicators can display power status, encoder signal status, and fault status, facilitating field maintenance personnel to quickly assess module operating status and encoder connection status. Made in Finland, manufactured by ABB's Finnish factory with reliable quality.
This module is widely used in the following industrial applications requiring precise speed and position feedback: metallurgical rolling mill main and auxiliary drives, paper machinery drive systems, printing machinery registration control, textile machinery synchronous drives, machine tool spindle and feed axis control, crane and hoist speed control, test stand dynamometer systems, elevator and escalator control, packaging machinery positioning control, food and beverage machinery drives, etc. In these applications, the NTAC-02 ensures the drive can obtain precise motor speed and position feedback, achieving high-precision closed-loop control to meet strict production process requirements for speed accuracy, positioning accuracy, and synchronization accuracy.
Note: This product NTAC-02 (58976008) is a pulse encoder interface option module for ABB ACS600/ACS800 series drives, and must be used with the corresponding drive model. The above parameters are confirmed based on ABB official installation and start-up guide and official Product Information Management (PIM) data sheet. Some parameters (such as specific signal level thresholds, mounting method, status indicator configuration, etc.) are subject to ABB official manual; Contact via email for confirmation. Installation and wiring must be performed by professional engineers with electrical operation qualifications, strictly following ABB drive installation manuals and electrical safety operation procedures.
2. Specifications
表格
| Parameter | Value |
|---|---|
| Brand | ABB (Asea Brown Boveri, Swiss/Swedish multinational group) |
| Product Series | ABB Drives |
| Model | NTAC-02 |
| Order No./Part No. | 58976008 |
| Product Type | Pulse Encoder Interface Module |
| Compatible Drives | ABB ACS600 series, ACS800 series industrial drives |
| Encoder Type | Incremental Pulse Encoder |
| Input Signals | A-phase, B-phase quadrature pulses, optional Z-phase (zero/index) pulse |
| Signal Levels | HTL (Push-Pull) / TTL (high-level threshold >7.6V, specific low-level threshold subject to official manual) |
| Max. Signal Frequency | 100 kHz |
| Direction Detection | A/B phase phase difference for forward/reverse detection |
| Position Counting | A/B phase pulse counting, Z-phase zero reference |
| Speed Measurement | Pulse frequency/period measurement |
| Encoder Supply Output | Jumper selectable 15V DC or 24V DC |
| Encoder Supply Protection | Short-circuit protection, overcurrent protection |
| Module Supply Voltage | 24V DC ±10% |
| Module Power Consumption | Approx. 7.5W (300mA) |
| Electrical Isolation | Electrical isolation between encoder input and drive control circuit |
| Signal Conditioning | Built-in filtering, shaping, level conversion circuits |
| Communication Interface | Drive internal bus / dedicated connector (communication with ACS600/ACS800 main control unit) |
| Status Indicators | Power LED, encoder signal LED, fault LED (specific configuration subject to official manual) |
| Mounting | Drive option slot installation / DIN rail mounting (specific subject to official manual) |
| Operating Temperature | -25°C ~ +70°C |
| Storage Temperature | Contact via email (reference -40°C ~ +85°C) |
| Relative Humidity | Contact via email (reference 5% ~ 95% non-condensing) |
| Protection Degree | IP20 (module installed inside drive/control cabinet) |
| EMC | Industrial grade (compliant with ABB drive EMC standards) |
| Vibration Resistance | Industrial grade (Contact via email for specific standards) |
| Certifications/Standards | Contact via email (CE, UL, cUL, etc.) |
| Origin | Finland |
| Dimensions (L×H×W) | Approx. 108mm × 75mm × 45mm (net dimensions, ABB official PIM data) |
| Weight | Approx. 0.5 kg (net weight, ABB official PIM data) |
| Tariff Code | 8538903000 (reference) |
| Matching Encoder | User-supplied incremental pulse encoder (HTL/TTL output, A/B/Z phases) |
| Matching Cable | User-supplied encoder cable (shielded twisted pair recommended) |
| Replacement Model | Contact via email for confirmation (NTAC-01 and earlier models) |
| Minimum Order Quantity | 1 unit |
| HS Code | 8538903000 (reference, Contact via email for confirmation) |
| Stock Status | Order available |
| Warranty | 12 months |
5. Model Explanation
Model: NTAC-02
Order No./Part No.: 58976008
Product Description: ABB pulse encoder interface module for ACS600/ACS800 series drives, incremental encoder A/B/Z phase input, max. 100kHz, HTL/TTL levels, encoder supply 15V/24V selectable, 24V DC supply, electrical isolation
NTAC-02 Model Overview:
- NTAC = Network / Pulse encoder Adapter Card, ABB Drives encoder interface module series
- 02 = Second generation/version number, supports HTL/TTL levels, max. 100kHz, encoder supply 15V/24V selectable
- Applicable to ABB ACS600 and ACS800 series industrial drives
- Incremental pulse encoder interface, A/B/Z phase input
- Electrical isolation design, protects drive control circuit
- Made in Finland, industrial-grade quality
Order No. 58976008 Explanation:
- 58976008 is the ABB globally unified order number/part number for the NTAC-02 pulse encoder interface module
- When purchasing, please provide both the model (NTAC-02) and order number (58976008) to ensure accurate supply
- EAN barcode and product identification subject to ABB official
NTAC Series Encoder Interface Modules (reference):
表格
| Model | Description |
|---|---|
| NTAC-01 | Earlier version pulse encoder interface module (Contact via email for compatibility confirmation) |
| NTAC-02 | Current version, HTL/TTL levels, max. 100kHz, encoder supply 15V/24V selectable (this product) |
| NTAC-03 and above | Contact via email for existence and functional differences |
Note: The above series information is for reference only. Specific model compatibility and replacement relationships are subject to ABB official technical documentation; Contact via email for confirmation.
Compatible Drive Series:
表格
| Drive Series | Description |
|---|---|
| ACS600 | ABB earlier high-performance industrial drive series, supports NTAC-02 encoder interface module |
| ACS800 | ABB mainstream high-performance industrial drive series, widely used in various industries, supports NTAC-02 encoder interface module |
| Other series | Contact via email for compatibility confirmation (e.g. ACS550, ACS355 may use different encoder interface module models) |
Related Products (ordered separately, Contact via email):
- Incremental pulse encoders (HTL/TTL output, A/B/Z phases, brands such as Leine & Linde, Kübler, Pepperl+Fuchs, etc.)
- Encoder cables (shielded twisted pair cables, length according to application requirements)
- ABB ACS600/ACS800 series drives
- ABB drive control panels (CDP 312R, etc.)
- ABB drive communication modules (Profinet, EtherNet/IP, Modbus TCP, Profibus DP, etc.)
- ABB drive I/O extension modules (NDIO-0x digital I/O, NAIO-0x analog I/O, etc.)
Official Documentation Reference:
- ABB Drives Installation and Start-up Guide: Pulse Encoder Interface Module NTAC-0x, Digital I/O Extension Module NDIO-0x, Analogue I/O Extension Module NAIO-0x (Document No.: en_ntac_ndio_naio_um_4a)
- ABB ACS600 User Manual and Hardware Manual
- ABB ACS800 User Manual and Hardware Manual
- ABB NTAC-02 Product Information Management (PIM) Data Sheet (EN_58976008)
6. Why Choose Us
- Professional Procurement, Genuine ABB Quality Guaranteed — All ABB encoder interface modules and drive options obtained through professional procurement channels, ensuring genuine ABB original products, with product identification, factory inspection certificates, and technical documentation, 12-month quality warranty. Pre-shipment appearance inspection, model confirmation, order number verification, connector check, board component integrity check, and packaging check performed.
- Worldwide Delivery, Professional Industrial Electronics Logistics — DHL/FedEx/UPS international courier, global delivery available. Encoder interface modules and other precision industrial electronic devices use shock-proof moisture-proof anti-static professional packaging (anti-static bag + foam cushioning + rigid carton), ensuring safe transport. Expedited logistics and customs clearance available, delivery to 200+ countries, meeting urgent project and equipment maintenance needs.
- Professional Technical Support, Drive System Full-process Service — Encoder interface module selection consultation (confirming drive model, encoder type, signal level, pulse frequency, supply voltage, cable length), installation guidance (drive option slot installation specifications, encoder wiring, shield grounding guidance, supply jumper setting), system commissioning (encoder parameter setting, speed feedback calibration, direction confirmation, zero signal testing, closed-loop control parameter tuning), fault analysis (encoder signal loss troubleshooting, counting error diagnosis, communication fault detection, power fault analysis, alarm code interpretation, spare parts replacement guidance), and drive system spare parts list review, helping users correctly select, install and maintain drive systems.
- Flexible Procurement, Project Bulk and Spare Parts Framework Agreements — Single unit and bulk project orders, tiered discounts. Complete drive system package solutions available (drive + encoder interface module + encoder + encoder cable + control panel + communication module + I/O extension module combination) and annual spare parts framework agreements, helping users optimize procurement cost, ensure spare parts supply, minimize equipment downtime risk. Customized quotations and long-term cooperation solutions available for metallurgy, paper, printing, textile, machine tools, cranes, test stands, elevators, and other industry users.
- Pre-shipment Verification, Test Report Available — Appearance, packaging, model, order number checks before shipment; encoder interface module test report available if necessary (appearance inspection, connector check, component integrity check, silkscreen identification verification, supply jumper check, packaging check, accessory inventory), ensuring delivered product in good condition. For urgent project needs (drive fault repair, production line emergency repair, project commissioning, equipment modification and upgrade), priority inventory coordination and expedited shipping available.
7. Frequently Asked Questions (FAQ)
Q1: What is ABB NTAC-02 58976008? What are the main parameters?
A: ABB NTAC-02 (order no. 58976008) is a Pulse Encoder Interface Module manufactured by ABB Drives, specifically designed for ABB ACS600 and ACS800 series industrial drives, used to connect incremental pulse encoder speed and position feedback signals to the drive for high-precision closed-loop speed control and position control.
Core parameters: Brand ABB, product series ABB Drives, model NTAC-02, order no./part no. 58976008, product type Pulse Encoder Interface Module, compatible drives ABB ACS600 series, ACS800 series, encoder type incremental pulse encoder, input signals A-phase B-phase quadrature pulses optional Z-phase zero pulse, signal levels HTL (Push-Pull)/TTL, max. signal frequency 100kHz, encoder supply output jumper selectable 15V DC or 24V DC, module supply voltage 24V DC ±10%, module power consumption approx. 7.5W (300mA), electrical isolation between encoder input and drive control circuit, operating temperature -25°C~+70°C, protection degree IP20, dimensions approx. 108mm×75mm×45mm (net), weight approx. 0.5kg (net), origin Finland.
Main applications: Widely used in industrial applications requiring precise speed and position feedback, including: metallurgical rolling mill main and auxiliary drives, paper machinery drive systems, printing machinery registration control, textile machinery synchronous drives, machine tool spindle and feed axis control, crane and hoist speed control, test stand dynamometer systems, elevator and escalator control, packaging machinery positioning control, food and beverage machinery drives, etc.
Note: This product is a drive option module and must be used with ABB ACS600/ACS800 series drives; it cannot function when used alone. User must supply incremental pulse encoder and encoder cable separately. Installation and wiring must be performed by professional engineers with electrical operation qualifications.
Q2: What types of encoders does NTAC-02 support? How to select an encoder?
A: The NTAC-02 supports incremental pulse encoders, with specific requirements as follows:
Supported encoder types:
- Output signals: A-phase, B-phase quadrature pulse signals, optional Z-phase (zero/index) pulse signal
- A and B phases with 90° phase difference (quadrature), used for rotation direction detection and counting
- Z-phase outputs one pulse per revolution, used for position homing and reference point positioning
- Signal levels:
- HTL (Push-Pull): High level typically 10-30V, strong anti-interference, long transmission distance, suitable for long-distance transmission in industrial fields
- TTL (RS-422 differential): High level typically 5V, high transmission rate, suitable for short-distance high-speed transmission
- NTAC-02 HTL input high-level threshold >7.6V, specific low-level threshold subject to official manual
- Max. pulse frequency: ≤ 100 kHz (NTAC-02 maximum input signal frequency)
- Supply voltage: Encoder power supplied by NTAC-02, jumper selectable 15V DC or 24V DC
- When selecting 15V supply, use 15V-powered encoder
- When selecting 24V supply, use 24V-powered encoder
- Can also use external independent power supply for encoder (note common ground and signal level matching)
How to select an encoder:
- Determine pulse count (PPR):
- Select encoder pulse count based on speed control accuracy and position control accuracy requirements
- Common pulse counts: 100, 250, 500, 600, 1000, 1024, 2000, 2048, 2500, 5000 PPR (pulses per revolution)
- Higher pulse count = higher speed and position feedback accuracy, but higher pulse frequency at same speed
- Must ensure pulse frequency at motor maximum speed does not exceed NTAC-02 100kHz limit
- Calculation formula: Max pulse frequency = (motor max speed RPM ÷ 60) × pulse count PPR
- Determine signal level type:
- Long-distance transmission (>10m), strong EMI environment → select HTL push-pull output encoder
- Short-distance transmission (<5m), high-rate application → select TTL/RS-422 differential output encoder
- Note NTAC-02 input level thresholds, ensure encoder output level matches
- Determine supply voltage:
- Select encoder with corresponding supply voltage based on NTAC-02 encoder supply jumper setting (15V or 24V)
- 24V-powered encoders commonly used in industrial fields, good compatibility
- Some high-precision encoders use 5V supply, requiring external 5V power supply, cannot use NTAC-02 15V/24V output
- Determine mechanical mounting form:
- Solid shaft encoder (requires coupling to connect to motor shaft)
- Hollow shaft/blind hollow shaft encoder (directly mounted on motor shaft)
- Through-hole shaft encoder (passes through motor shaft)
- Select appropriate mounting form based on motor shaft diameter and installation space
- Determine protection degree and environmental adaptability:
- Normal indoor environment → IP54/IP64
- Humid, dusty, outdoor environment → IP65/IP67
- High-temperature environment → select high-temperature resistant model
- Strong vibration environment → select vibration-resistant model
Recommended encoder brands (reference):
- Leine & Linde (Sweden, well-known industrial encoder brand)
- Kübler (Germany)
- Pepperl+Fuchs (P+F)
- Siemens
- Turck
- ELCO
- Other incremental encoders with HTL/TTL output, A/B/Z phases, 15V/24V supply
For encoder selection assistance, please provide drive model, motor rated speed and maximum speed, speed/position accuracy requirements, encoder installation space, cable length, operating environment, etc.; Contact via email, we can assist in recommending suitable encoder models.
Q3: How to install and wire NTAC-02? What should be noted?
A: NTAC-02 installation and wiring must be performed by professional engineers with electrical operation qualifications, strictly following ABB drive installation manuals and electrical safety operation procedures. The following are general reference steps:
Pre-installation preparation:
- Confirm compatibility: Confirm NTAC-02 is compatible with your drive model (ACS600/ACS800), confirm drive firmware version supports encoder interface function
- Safety power-off: Disconnect drive main power and control power, wait for drive internal capacitors to fully discharge (wait at least 5 minutes, specific subject to discharge time specified in drive manual), confirm DC bus voltage has dropped to safe level
- Prepare tools: Prepare Phillips screwdriver, anti-static wrist strap, multimeter, wire stripper, crimping tool, etc.
- Prepare materials: NTAC-02 module, incremental encoder, shielded twisted pair encoder cable, cable glands, cable ties, etc.
Installation steps (reference):
- Power off and discharge: Disconnect all drive power supplies, wait for capacitor discharge, use multimeter to confirm DC bus voltage < 36V (safe voltage)
- Open drive cover: Loosen fixing screws of drive front cover/wiring compartment cover, remove cover
- Anti-static: Wear anti-static wrist strap and ground reliably to prevent electrostatic damage to module
- Install NTAC-02 module:
- Locate option slot/connector position inside drive (specific location reference drive hardware manual)
- Align NTAC-02 module with slot, insert smoothly, ensure connector fully engaged
- Fix module to drive frame with fixing screws
- Set encoder supply jumper:
- Based on encoder supply voltage requirement, set NTAC-02 supply jumper to 15V or 24V
- Jumper setting location and method reference NTAC-02 installation manual
- Connect encoder cable:
- Connect one end of encoder cable to encoder
- Route the other end into drive wiring compartment, connect to NTAC-02 module encoder wiring terminals
- Wiring definition reference NTAC-02 installation manual (usually includes: A+, A-, B+, B-, Z+, Z-, encoder supply+, encoder supply-, shield ground, etc.)
- Ensure wiring is secure, no looseness
- Shield grounding:
- Encoder cable shield should be single-end grounded at drive side (usually connected to drive ground terminal/shield grounding bar)
- Encoder side shield treatment method reference encoder manual (usually not grounded or grounded through capacitor)
- Avoid grounding shield at both ends to form ground loop
- Check and organize:
- Check all wiring is correct, no short circuits, no looseness
- Organize cables, secure with cable ties, avoid cables contacting hot components and moving parts
- Confirm no tools, screws, or other foreign objects left inside drive
- Restore cover: Reinstall drive front cover/wiring compartment cover, tighten fixing screws
- Power-on test:
- First turn on control power, observe NTAC-02 module status indicators
- Power indicator should be steady on (green)
- Encoder signal indicator should blink when motor rotates
- Fault indicator should not be steady on
- Then turn on main power, check encoder feedback speed and position via drive control panel
Wiring precautions:
- Cable selection: Must use shielded twisted pair cable, A-phase and B-phase should each use twisted pair, shield coverage recommended ≥ 85%. Cable length determined by signal level and environment, HTL signals typically up to 100-300m, TTL signals typically no more than 10-30m.
- Cable routing: Encoder cables should be routed separately from power cables (motor cables, drive output cables), minimum spacing recommended ≥ 20cm, avoid parallel routing. If crossing is necessary, cross perpendicularly. Encoder cables should not be in the same cable tray/trunking as power cables.
- Shield grounding: Shield single-end grounded (usually at drive side), avoid grounding at both ends to form ground loop. If large ground potential difference at site, consider using isolated encoder or signal isolator.
- Wiring terminals: Ensure all wiring terminals are tight, avoid loosening due to vibration. Stranded flexible wires should be crimped with ferrules (cord end terminals) before connecting to terminals.
- Encoder supply: Confirm encoder supply voltage (15V/24V) matches encoder rated voltage, jumper setting correct. Encoder supply circuit has short-circuit protection, but wiring short circuits should still be avoided.
- Signal level matching: Confirm encoder output level (HTL/TTL) matches NTAC-02 input level. If encoder output is 5V TTL and NTAC-02 input is HTL threshold, signal recognition may be abnormal, requiring signal conversion module or selecting appropriate encoder.
- A/B phase sequence: If after power-on the speed feedback direction is opposite (forward shows negative speed), swap A-phase and B-phase wiring, or set reverse direction via drive parameters.
- Z-phase connection: If zero positioning function not required, Z-phase can be left unconnected. If position homing function required, Z-phase must be connected and related parameters correctly set.
Specific installation location, wiring terminal definitions, jumper settings, parameter configuration, etc. are subject to ABB NTAC-02 installation and start-up guide and corresponding drive hardware manual. For installation guidance or technical support, Contact via email.
Q4: In stock? Lead time? Price?
A: Currently Order Available. Specific stock of ABB drive option modules fluctuates with market.
- Lead time: Standard 4-8 weeks (ABB drive option modules are industrial-grade products, some common models may be in stock, specific subject to formal quotation).
- Price: Subject to formal quotation, depends on specific model, quantity, supply channel, whether includes technical service and on-site commissioning support, etc. Bulk procurement enjoys tiered discounts.
- Package solutions: Complete drive system package solutions available (drive + encoder interface module + encoder + encoder cable + control panel + communication module + I/O extension module combination), combined procurement price more favorable. If the project requires encoders and cables, it is recommended to purchase at the same time.
- Expedited service: For urgent needs (drive fault repair, production line emergency repair, project commissioning, equipment modification and upgrade), we can try to coordinate stock or expedited ordering, please contact sales team.
- Please indicate: required quantity, desired delivery time and destination, drive model (ACS600 or ACS800 and specific specifications), whether matching encoder and cable needed, whether installation commissioning and technical support services needed when inquiring; we will coordinate fastest delivery and optimal price.