Products

Classification

Company Culture    Electrical    High & Low Voltage Electrical Equipment    MCB / MCCB    ABB S202-C20 Miniature Circuit Breaker 2P C-Curve 20A S200 Series

ABB S202-C20 Miniature Circuit Breaker 2P C-Curve 20A S200 Series

Swiss ABB S202-C20 miniature circuit breaker, part of the System pro M compact S200 series, 2-pole (2P) design, C tripping characteristic, rated current 20A, rated breaking capacity 6kA (230/400V AC), rated voltage 230/400V AC, frequency 50/60Hz, thermal-magnetic trip, providing both overload protection and short-circuit protection, current limiting design, IEC/EN 60898-1 compliant, 35mm standard DIN rail mounting, modular design, wiring capacity 35mm², mechanical life 20000 operations, protecti
online consultation

Product Details

I. Product Overview

The ABB S202-C20 is a System pro M compact S200 series miniature circuit breaker (MCB) manufactured by Swiss ABB, with 2-pole (2P) design, C tripping characteristic, rated current 20A, and rated breaking capacity 6kA. This miniature circuit breaker adopts a current limiting design, featuring two different tripping mechanisms - a delayed thermal tripping mechanism for overload protection and an electromechanical tripping mechanism for short-circuit protection, providing reliable overload and short-circuit protection for electrical circuits and equipment.

The S200 series is ABB's classic modular DIN rail mounted miniature circuit breaker series, offering multiple tripping characteristics (B, C, D, K, Z), multiple pole configurations (1P, 1P+N, 2P, 3P, 3P+N, 4P), breaking capacities up to 6kA (230/400V AC), and rated currents up to 63A. The S200 series complies with IEC/EN 60898-1 and IEC/EN 60947-2 standards, has passed multiple international certifications, and is widely used in industrial distribution, commercial buildings, residential electrical, control cabinets and other fields.

The S202-C20 is the 2-pole version, suitable for single-phase two-wire circuit (L+N) protection or two independent single-phase circuit protection, and can also be used for simultaneous line+neutral interruption protection of single-phase equipment. The 20A rated current is suitable for larger power single-phase distribution circuits, such as high-power socket circuits, electric water heaters, air conditioners, kitchen equipment, small electric heating equipment and other loads for overload and short-circuit protection. The C tripping characteristic is suitable for inductive loads and general distribution circuits, with an instantaneous tripping range of 5-10 times the rated current, capable of withstanding a certain degree of starting inrush current, while providing reliable overload and short-circuit protection. The product adopts thermal-magnetic tripping principle: thermal trip for overload protection (bimetallic strip) and magnetic trip for short-circuit protection (electromagnetic coil), with stable and reliable tripping characteristics. The product has a rated voltage of 230/400V AC (400V for 2P), rated insulation voltage 440V, rated impulse withstand voltage 4kV, frequency 50/60Hz. It adopts 35mm standard DIN rail mounting with modular design, and the S202-C20 occupies 2 modules (35mm). The wiring capacity is suitable for conductors up to 35mm², mechanical life 20000 operations, operating temperature -25~+55°C, protection class IP20 (IP40 with cover).

II. Specifications

表格

Parameter Value
Brand ABB
Series System pro M compact S200
Model S202-C20
Product Type Miniature Circuit Breaker (MCB)
Number of Poles 2P
Rated Current (In) 20 A
Tripping Characteristic C (instantaneous trip range 5~10×In)
Trip Unit Type Thermal-magnetic
Rated Operating Voltage (Ue) 230/400 V AC
Rated Insulation Voltage (Ui) 440 V
Rated Impulse Withstand Voltage (Uimp) 4 kV
Rated Frequency 50/60 Hz
Rated Breaking Capacity (Icn) 6 kA (230/400 V AC)
Rated Ultimate Short-Circuit Breaking Capacity (Icu) 6 kA (230/400 V AC)
Rated Service Short-Circuit Breaking Capacity (Ics) 6 kA (230/400 V AC)
Utilization Category Category A (per IEC/EN 60898-1)
Mounting 35mm standard DIN rail
Module Width 2 modules (35mm)
Wiring Capacity Max. 35 mm²
Terminal Type Double terminal/cage terminal (contact via email for confirmation)
Mechanical Life 20000 operations
Electrical Life Contact via email for confirmation (over 10000 operations)
Operating Temperature -25 to +55 °C
Storage Temperature -40 to +70 °C
Reference Ambient Temperature 30 °C
Degree of Protection IP20 (IP40 with cover)
Pollution Degree 3
Applicable Standards IEC/EN 60898-1, IEC/EN 60947-2
Approvals CE, CCC, EAC, etc. (contact via email for confirmation)
Dimensions Standard 2-pole modular size (contact via email for confirmation)
Weight Contact via email for confirmation
Country of Origin Contact via email for confirmation (China/Switzerland/India, etc.)

III. Product Features

  • ABB quality, System pro M compact S200 series classic miniature circuit breaker, reliable performance
  • 2-pole (2P) design, suitable for single-phase two-wire circuit or two independent single-phase circuit protection
  • 20A rated current, suitable for larger power single-phase distribution circuits
  • C tripping characteristic, instantaneous trip range 5~10×In, balancing starting inrush current and protection reliability
  • Thermal-magnetic trip mechanism, thermal trip for overload protection + magnetic trip for short-circuit protection, dual protection reliable
  • Current limiting design, fast interruption of short-circuit current, effectively limiting fault energy
  • Rated breaking capacity 6kA (230/400V AC), meeting general industrial and civil distribution requirements
  • Rated voltage 230/400V AC, rated insulation voltage 440V, rated impulse withstand voltage 4kV
  • IEC/EN 60898-1 and IEC/EN 60947-2 compliant, multiple international certifications
  • 35mm standard DIN rail mounting, modular design, easy installation
  • 2 module width (35mm), standard modular layout
  • Wiring capacity up to 35mm², suitable for common conductor specifications
  • Mechanical life 20000 operations, durable
  • Operating temperature -25~+55°C, wide temperature adaptation
  • Protection class IP20 (IP40 with cover), safe and reliable
  • Environmentally friendly, RoHS compliant
  • Widely used in industrial distribution, commercial buildings, residential electrical, control cabinets and other fields

IV. Typical Applications

  • Overload and short-circuit protection for single-phase circuits in industrial distribution systems
  • Single-phase electrical circuit protection in commercial buildings and office buildings
  • Circuit protection in residential electrical distribution boards
  • Power circuit protection in control cabinets and control panels
  • Protection of high-power socket circuits (air conditioners, electric water heaters, kitchen equipment, etc.)
  • Line protection for single-phase motors, pumps, fans and other equipment
  • Distribution protection for HVAC equipment
  • Protection for electric heating equipment (electric boilers, heaters, water heaters, etc.)
  • Distribution protection for automated production lines and machinery
  • Protection for temporary power and construction distribution

V. Model Description

S202-C20 is the complete model number for the ABB S200 series miniature circuit breaker. Where:

  • S: System pro M series
  • 2: S200 series
  • 0: Breaking capacity code (standard 6kA type)
  • 2: Number of poles (2-pole/2P)
  • C: Tripping characteristic (C)
  • 20: Rated current (20A)

The ABB S200 series miniature circuit breaker model coding rules are as follows:

  • Series: S200 (6kA standard), S200M (10kA high breaking capacity), S200P (25kA ultra-high breaking capacity), S200U (UL standard), S200 series UC (DC type), etc.
  • Number of poles: 1=1P, 2=2P, 3=3P, 4=4P (also 1P+N, 3P+N, etc.)
  • Tripping characteristic: B (3~5×In), C (5~10×In), D (10~14×In), K, Z, etc.
  • Rated current: 2A, 4A, 6A, 10A, 16A, 20A, 25A, 32A, 40A, 50A, 63A, etc.
  • Accessories: auxiliary contacts (S2C-H...), alarm contacts, shunt trip, undervoltage trip, busbar, etc. optional

The S202-C20 is a 2-pole, C characteristic, 20A rated current standard 6kA breaking capacity miniature circuit breaker. To confirm the detailed configuration of this model (terminal type, dimensions, weight, certification details, accessory compatibility, etc.), please contact via email for confirmation. We will provide detailed technical documentation and selection support.

VI. Why Choose Us

  • Professional channel supply, comprehensive model coverage across multiple brands of industrial spare parts
  • Strict quality inspection process ensuring reliable product quality
  • Professional engineering team providing technical support and selection consultation
  • Quick response, efficient logistics, orders accepted
  • Quality assurance, worry-free after-sales service

VII. FAQ

Q1: What is the difference between a 2P circuit breaker and two 1P circuit breakers?

A: A 2P circuit breaker integrates two poles in one housing, achieving synchronized on/off through internal mechanical linkage, capable of simultaneously interrupting the phase conductor and neutral conductor (or two phase conductors), ensuring synchronized operation of both poles during faults, avoiding phase loss or safety hazards caused by single-pole interruption. Two combined 1P circuit breakers do not have synchronized linkage function and may have asynchronous interruption due to mechanical differences. For single-phase circuits requiring simultaneous phase and neutral interruption (such as electric water heaters, air conditioners, etc.), a 2P circuit breaker is recommended. The S202-C20 features synchronized 2-pole linkage design with higher reliability.

Q2: What loads is a 20A rated current circuit breaker suitable for?

A: A 20A rated current miniature circuit breaker is suitable for distribution circuits with rated current not exceeding 20A, corresponding to approximately 4.6kW for single-phase (230V) load power. Typical applications include: high-power socket circuits (air conditioners, electric water heaters, kitchen equipment, etc.), single-phase motors (1-5kW), electric heating equipment, HVAC equipment, etc. In actual selection, the load type, starting current, line length and prospective short-circuit current should be comprehensively considered, and it is recommended that selection be performed by professional electrical engineers.

Q3: What does C tripping characteristic mean?

A: The C characteristic is a classification of the instantaneous tripping characteristic of miniature circuit breakers, indicating that the instantaneous trip range is 5-10 times the rated current (5~10×In). That is, when a short-circuit current of 5-10 times the rated current (100~200A) appears in the circuit, the S202-C20 trips instantly to interrupt the circuit. The C characteristic is suitable for general distribution circuits and inductive loads (such as motors, transformers, fluorescent lamps, etc.), capable of withstanding a certain degree of starting inrush current while providing reliable overload and short-circuit protection. By comparison, the B characteristic (3~5×In) is suitable for purely resistive loads and lighting circuits, and the D characteristic (10~14×In) is suitable for high inrush current loads.

Q4: Can you provide mounting dimensions and accessory compatibility information for this model?

A: Yes. Please contact via email with your requirements, including installation environment, conductor specifications, whether accessories are needed (auxiliary contacts, alarm contacts, shunt trip, undervoltage trip, busbar, etc.), and we will provide corresponding outline dimension drawings, installation guides, accessory selection recommendations and technical support. The S200 series supports various accessories to meet different application requirements.