Products

Classification

Company Culture    Electrical    High & Low Voltage Electrical Equipment    Soft Starters    Schneider ATS22C59Q Altistart 22 Soft Starter 590A

Schneider ATS22C59Q Altistart 22 Soft Starter 590A

Schneider ATS22C59Q Altistart 22 soft starter, Schneider Electric ATS22 series, line rating 590A, control voltage 220V, supply 230V/160kW to 400~440V/355kW, 3-phase, built-in bypass, IP00, used for soft starting and soft stopping of asynchronous motors, smooth starting avoiding mechanical stress, widely used in industrial drive systems.
online consultation

Product Details

I. Product Overview

The Schneider ATS22C59Q is a soft starter from the Altistart 22 series manufactured by Schneider Electric of France, model ATS22C59Q. This soft starter has a line rating of 590A, control voltage of 220V, supply voltage 230~440V, suitable for 160kW motors at 230V, 315kW motors at 400V and 355kW motors at 440V, used for soft starting and soft stopping of three-phase asynchronous motors, achieving smooth motor start, reducing starting current and avoiding mechanical shock.

The Altistart 22 (ATS22) is Schneider Electric's classic soft starter series, covering 4~400kW, designed for three-phase squirrel-cage asynchronous motors, achieving smooth start/stop via voltage and torque control. The ATS22C59Q has a factory setting current of 560A, power dissipation of 251W in standard applications, utilization category AC-53A, torque-controlled starting (current limited to 3.5 In), and class 10 motor protection in standard applications. It features a built-in bypass, heat sink mounting, and forced convection cooling.

The ATS22C59Q has a control voltage of 220V, three-phase application, protection rating IP00. This soft starter can be connected in the motor supply line (inline) or in the motor delta (inside delta). Communication is Modbus (RS485, RJ45, baud rate 4800/9600/19200bps); optional Fipio, PROFIBUS DP, DeviceNet, Modbus TCP. It has 3 logic inputs (24V), 2 relay outputs, and supports PTC probe input (750Ω). Operating temperature -10~40°C (without derating), 40~60°C with 2.2%/°C current derating. Dimensions 304×339.7×455mm, net weight 50kg. It is widely used in pumps, fans, conveyors, compressors and other industrial drive applications.

II. Specifications

表格

Parameter Value
Brand Schneider Electric (France)
Model ATS22C59Q
Product Type Soft Starter
Series Altistart 22 (ATS22)
Line Rating (IcL) 590 A
Factory Setting Current 560 A
Control Voltage 220 V (50/60Hz)
Supply Voltage 230~440 V (-15%~+10%, range 195~484V)
Motor Power 160kW at 230V; 315kW at 400V; 355kW at 440V
Phases 3-phase
Utilization Category AC-53A
Starting Method Torque-controlled start (current limited to 3.5 In)
Motor Protection Class 10 in standard applications
Built-in Bypass Yes
Power Dissipation 251 W (standard applications)
Protection Rating IP00
Cooling Forced convection (with heat sink)
Logic Inputs 3 (24V)
Relay Outputs 2
PTC Probe Input 750 Ω
Communication Modbus (RS485, RJ45, 4800/9600/19200bps)
Optional Fieldbus Fipio / PROFIBUS DP / DeviceNet / Modbus TCP
Supply Frequency 50/60Hz (-10%~+10%), network 45~66Hz
Operating Temperature -10~40°C (without derating); 40~60°C (2.2%/°C derating)
Storage Temperature -25~70°C
Humidity 0~95% (non-condensing)
Noise 56 dB
Dimensions 304 (W) × 339.7 (D) × 455 (H) mm
Net Weight 50 kg
Mounting Position Vertical ±10°
Protection Functions Phase loss, motor thermal, starter thermal
Standard IEC/EN 60947-4-2
Approvals CCC, CSA, UL, GOST, C-Tick, CE
Applicable Motor Three-phase squirrel-cage asynchronous motor
Typical Loads Pumps, fans, conveyors, compressors
Manufacturer Schneider Electric (France)

III. Product Features

  • Schneider Altistart 22 soft starter
  • Model ATS22C59Q, line rating 590A
  • Control voltage 220V, supply 230~440V
  • Suitable for 160~355kW three-phase asynchronous motors
  • Soft start/soft stop, smooth starting
  • Torque control, current limited to 3.5 In
  • Built-in bypass, reduces heat
  • Avoids mechanical stress, extends equipment life
  • Reduces starting current, minimizes grid shock
  • Slim design for mounting versatility
  • Integrated Modbus, multiple fieldbus options
  • Class 10 motor protection in standard applications
  • Comprehensive phase loss and thermal protection

IV. Typical Applications

  • Water pump soft start control
  • Fan soft starting
  • Conveyor drives
  • Compressor soft starting
  • Crushers and mixers
  • Conveying equipment
  • Industrial pumps and fans
  • Three-phase asynchronous motor start control

V. Model Description

The ATS22C59Q fields are explained as follows:

  • ATS22: Schneider Altistart 22 soft starter series
  • C: Design/size code
  • 59: Line rating 590A
  • Q: Control voltage code (220V)

Note: This soft starter supports both inline connection and motor delta connection, with built-in bypass. To confirm bypass contactor, terminal configuration and other details, please contact via email for confirmation. We will provide technical documentation and selection support.

VI. Why Choose Us

  • Professional channel supply, comprehensive model coverage across multiple brands of industrial spare parts
  • Strict quality inspection process ensuring reliable product quality
  • Professional engineering team providing technical support and selection consultation
  • Quick response, efficient logistics, orders accepted
  • Quality assurance, worry-free after-sales service

VII. FAQ

Q1: What is ATS22C59Q?

A: ATS22C59Q is a Schneider Altistart 22 series soft starter, line rating 590A, control voltage 220V, suitable for 160~355kW three-phase asynchronous motors.

Q2: What are the key parameters of this soft starter?

A: Line rating 590A, control voltage 220V, supply 230~440V, 160kW at 230V / 315kW at 400V / 355kW at 440V, 3-phase, IP00, built-in bypass, integrated Modbus, net weight 50kg.

Q3: What protection functions does this soft starter have?

A: It has phase loss protection, motor thermal protection and starter thermal protection, with class 10 motor protection in standard applications.

Q4: How to confirm this soft starter's compatibility with the existing motor?

A: Please provide the existing motor power, rated voltage and rated current, contact via email, and we will assist in confirming compatibility and provide technical documentation.