Schneider ATS48C11Q Altistart 48 Soft Starter 100A
I. Product Overview
The Schneider ATS48C11Q is a soft starter from the Altistart 48 series manufactured by Schneider Electric of France, model ATS48C11Q. This soft starter has a line rating of 100A, control voltage of 220V, supply voltage 230~415V, suitable for 22~45kW in heavy duty and 30~90kW in standard duty three-phase asynchronous motors, used for soft starting and soft stopping, achieving smooth motor start, reducing starting current and avoiding mechanical shock.
The Altistart 48 (ATS48) is Schneider Electric's premium soft starter series, designed for heavy industry and pump applications, covering 4~1200kW. This series features TCS (Torque Control System), achieving smooth start/stop via both voltage and torque control, supporting standard and heavy duty applications. The ATS48C11Q has utilization category AC-53A, supports optional external bypass, and provides comprehensive motor protection.
The ATS48C11Q is a three-phase application with protection rating IP20. This soft starter can be connected in the motor supply line (inline) or in the motor delta (inside delta), with inside delta connection supporting up to 90kW. Communication is Modbus (RS485, RJ45, baud rate 4800/9600/19200bps). It supports 5 logic inputs (including PTC probe 750Ω), 2 logic outputs and 3 relay outputs (fault, end of start, motor energized), with analog current output 0-20mA/4-20mA. Dimensions 190×235×290mm, net weight 8.3kg. It is widely used in pumps, fans, compressors and other applications.
II. Specifications
表格
| Parameter | Value |
|---|---|
| Brand | Schneider Electric (France) |
| Model | ATS48C11Q |
| Product Type | Soft Starter |
| Series | Altistart 48 (ATS48) |
| Line Rating (Standard/Heavy Duty) | 100 A |
| Control Voltage | 220 V (50/60Hz) |
| Supply Voltage | 230~415 V (-15%~+10%) |
| Motor Power | Heavy duty: 230V/22kW, 400V/45kW; Standard: 230V/30kW, 400V/55kW; inside delta up to 90kW |
| Phases | 3-phase |
| Utilization Category | AC-53A |
| Start Control | TCS Torque Control System (current limited to 5 In) |
| Bypass | External bypass (optional) |
| Protection Rating | IP20 |
| Logic Inputs | 5 (Stop, Run, LI3, LI4), PTC probe 750Ω supported |
| Logic Outputs | 2 (0V common, configurable) |
| Relay Outputs | 3 (fault NO, end of start NO, motor energized NO) |
| Analog Output | Current output 0-20mA / 4-20mA |
| Communication | Modbus (RS485, RJ45, 4800/9600/19200bps) |
| Supply Frequency | 50/60Hz (-5%~+5%) |
| Operating Temperature | -10~40°C (without derating); 40~60°C (2%/°C derating) |
| Storage Temperature | -25~70°C |
| Humidity | 0~95% (non-condensing) |
| Operating Altitude | ≤1000m (no derating); >1000~2000m (2.2%/100m derating) |
| Mounting Position | Vertical ±10° |
| Dimensions | 190 (W) × 235 (D) × 290 (H) mm |
| Net Weight | 8.3 kg |
| Protection Functions | Phase loss, motor thermal, starter thermal |
| Standard | EN/IEC 60947-4-2 |
| Approvals | C-Tick, GOST, SEPRO, NOM 117, CSA, TCF, DNV, CCC, UL, CE |
| Applicable Motor | Three-phase squirrel-cage asynchronous motor |
| Typical Applications | Heavy industry, pumps, fans, compressors |
| Manufacturer | Schneider Electric (France) |
III. Product Features
- Schneider Altistart 48 soft starter
- Model ATS48C11Q, line rating 100A
- Control voltage 220V, supply 230~415V
- Suitable for 22~90kW motors
- TCS torque control system, smooth start/stop
- Supports standard and heavy duty applications
- External bypass design (optional)
- Pump soft stop function, avoids water hammer
- Avoids mechanical stress, extends equipment life
- Reduces starting current, minimizes grid shock
- Rich IO interfaces with Modbus communication
- Comprehensive motor protection
- Suitable for heavy industry applications
IV. Typical Applications
- Water pump soft start and soft stop control
- Fan soft starting
- Conveyor drives
- Compressor soft starting
- Crushers and mixers
- Conveying equipment
- Heavy industrial drives
- Three-phase asynchronous motor start control
V. Model Description
The ATS48C11Q fields are explained as follows:
- ATS48: Schneider Altistart 48 soft starter series
- C: Supply voltage code (230~415V)
- 11: Model code (line rating 100A)
- Q: Control voltage code (220V)
Note: This soft starter supports both inline connection and motor delta connection, with external bypass optional. To confirm bypass contactor, control voltage, terminal configuration and other details, please contact via email for confirmation. We will provide technical documentation and selection support.
VI. Why Choose Us
- Professional channel supply, comprehensive model coverage across multiple brands of industrial spare parts
- Strict quality inspection process ensuring reliable product quality
- Professional engineering team providing technical support and selection consultation
- Quick response, efficient logistics, orders accepted
- Quality assurance, worry-free after-sales service
VII. FAQ
Q1: What is ATS48C11Q?
A: ATS48C11Q is a Schneider Altistart 48 series soft starter, line rating 100A, control voltage 220V, suitable for 22~90kW three-phase asynchronous motors.
Q2: What are the key parameters of this soft starter?
A: Line rating 100A, control voltage 220V, supply 230~415V, heavy duty 22~45kW / standard 30~90kW, 3-phase, IP20, TCS torque control, Modbus communication, net weight 8.3kg.
Q3: What protection functions does this soft starter have?
A: It has phase loss protection, motor thermal protection and starter thermal protection, supporting PTC motor temperature probe input.
Q4: How to confirm this soft starter's compatibility with the existing motor?
A: Please provide the existing motor power, rated voltage and rated current, contact via email, and we will assist in confirming compatibility and provide technical documentation.