KSB ETABLOC-GN 040-160/074 G01 Close-Coupled Centrifugal Pump
1. Product Overview
ETABLOC-GN 040-160/074 G01 is a KSB Etabloc-series standardized single-stage, single-suction close-coupled (monoblock) volute pump, with hydraulic ratings and main dimensions to EN 733 (formerly DIN 24255). Unlike the long-coupled Etanorm, the Etabloc casing mounts directly onto the motor flange — pump and motor share one shaft with no coupling — giving a compact footprint.
In the model: GN = material/design version; 040 = nominal discharge DN40 (suction DN65 per EN 733); 160 = nominal impeller diameter 160 mm; /074 = impeller trimmed to duty / configuration code; G01 = design version. On a 2-pole motor (~2900 r/min) this size typically delivers Q ≈ 15–25 m³/h at H ≈ 20–30 m, with high efficiency and smooth running.
It handles clean water, cooling/chilled water and similar fluids; for thermal oil use the Etabloc SYT version.
2. Specifications
表格
| Item | Specification |
|---|---|
| Manufacturer | KSB |
| Model | ETABLOC-GN 040-160/074 G01 |
| Product type | Single-stage, single-suction close-coupled (monoblock) volute pump |
| Standard | EN 733 (formerly DIN 24255) |
| Design | Close-coupled, casing on motor flange, no coupling |
| Suction nozzle | DN65 (per EN 733 for DN40 discharge) |
| Discharge nozzle | DN40 |
| Nominal impeller dia. | 160 mm (/074 = trimmed/configured) |
| Typical duty | Q ≈ 15–25 m³/h, H ≈ 20–30 m (2900 r/min) |
| Max. working pressure | 16 bar |
| Fluid temperature | −30 to +140 °C (standard) |
| Casing material | Cast iron EN-GJL-250 |
| Impeller | Closed radial, trim-to-duty |
| Seal | Mechanical seal (EN 12756) |
| Drive | 2-pole three-phase motor (~2900 r/min), close-coupled |
| Installation | Horizontal |
5. Model Information
- Model: ETABLOC-GN 040-160/074 G01
- Product description: KSB Etabloc close-coupled single-stage pump, EN 733, DN40 discharge, 160 mm impeller.
- Model decode: ETABLOC = close-coupled standard volute pump series; GN = material/design version; 040 = discharge DN40; 160 = nominal impeller diameter 160 mm; /074 = trim-to-duty/config code; G01 = design version. Duty point, trim and motor are selected by flow, head and fluid. Please email us.
- Series features:
- EN 733 standard, high interchangeability
- Compact close-coupled design, no coupling
- Closed radial impeller, trim-to-duty for energy saving
- Mechanical seal EN 12756, low vibration
- Up to 16 bar, −30 to +140 °C
- Water supply, cooling circuits, HVAC, general industry
- Related products in series: Etabloc Pro / Etabloc MyFlow (integrated VSD); Etabloc SYT (thermal oil); Etanorm (long-coupled)
- Matching products: KSB motor, mechanical seal, base frame
6. Why Choose Us
- Exact model match: We verify ETABLOC-GN 040-160/074 G01 as supplied.
- Authorized channel supply: KSB Etabloc standard pumps through regular channels.
- Selection support: We help confirm duty point, impeller trim and motor.
- Delivery & after-sales: Quotation, lead-time confirmation and order follow-up provided; for questions, please email us.
7. FAQ
Q1: What is ETABLOC-GN 040-160/074 G01?
A: A KSB Etabloc close-coupled single-stage, single-suction standard pump, EN 733, DN40 discharge, 160 mm impeller.
Q2: Etabloc vs Etanorm?
A: Etabloc is compact, casing bolted to the motor flange (no coupling); Etanorm is long-coupled with a bearing bracket, allowing pump service without moving the motor.
Q3: What do the numbers mean?
A: 040 = discharge DN40; 160 = nominal impeller diameter 160 mm; /074 = trim/config code; G01 = design version.
Q4: Flow and head?
A: At 2-pole (~2900 r/min), typically Q=15–25 m³/h, H=20–30 m; see selection curve for the exact point.
Q5: Max pressure/temperature?
A: Standard version up to 16 bar, fluid −30 to +140 °C.
Q6: What fluids?
A: Clean water, cooling/chilled water and similar fluids; use SYT for thermal oil. For motors/seals, please email us.