Yokogawa AAI143-S53/A4D00 Analog Input Module (16-Channel, 4-20 mA, Isolated)

Yokogawa AAI143-S53/A4D00 analog input module, Japan Yokogawa CENTUM VP FIO current input module, 16-channel isolated input for 4-20 mA signals, accuracy ±16 μA with 10 ms data update period, 1500 V AC withstanding voltage between input and system, supports HART communication and per-channel 2-wire/4-wire transmitter setting, suffix S53 includes ISA Standard G3 and -20 to 70°C temperature options, suitable for DCS process signal acquisition.
online consultation

Product Details

I. Product Overview

The Yokogawa AAI143-S53/A4D00 is an analog input module (current input type) for CENTUM VP FIO, providing 16 isolated input channels that receive 4 to 20 mA DC signals from the field.

The module has a 1500 V AC (1 minute) withstanding voltage between input and system, with no insulation between channels. Accuracy is ±16 μA and the data update period is 10 ms; the input resistance varies from 270 Ω (20 mA) to 350 Ω (4 mA) when powered and is 500 kΩ or greater when powered off. The module can supply power to 2-wire transmitters, and each channel can be set for 2-wire or 4-wire transmitter input via setting pins, with HART communication supported.

Suffix code S53 corresponds to standard type, no explosion protection, and the ISA Standard G3 option with the -20 to 70°C temperature option.

II. Specifications

表格

Parameter Value
Brand Yokogawa (Japan)
Model AAI143-S53/A4D00
Series CENTUM VP FIO analog I/O modules
Product Type Analog input module (current input, isolated)
Input Channels 16, isolated (no insulation between channels)
Input Signal 4 to 20 mA DC
Allowable Input Current 24 mA
Input Resistance Power ON: 270 Ω (20 mA) to 350 Ω (4 mA); power OFF: ≥500 kΩ
Accuracy ±16 μA
Data Update Period 10 ms
Withstanding Voltage Between input and system: 1500 V AC for 1 minute (500 V AC with dedicated cable)
Transmitter Power Supply ≥19.0 V at 20 mA; ≤25.5 V at 0 mA (output current limit 25 mA)
2-wire/4-wire Setting Per channel via setting pin
Temperature Drift ±16 μA / 10°C
Maximum Current Consumption 230 mA (5 V DC), 540 mA (24 V DC)
HART Communication Available (EB401 firmware rev. 2 or later when installed in ER bus node unit with HART function)
External Connection Pressure clamp terminal, MIL connector cable, dedicated cable (KS1)
Mass 0.3 kg
Suffix Code Meaning S standard type; 5 no explosion protection; 3 with ISA Standard G3 option and temperature (-20 to 70°C) option

V. Model Description

In AAI143-S53/A4D00, AAI143 is the analog input module model (4 to 20 mA, 16-channel, isolated); suffix S denotes standard type, 5 denotes no explosion protection, 3 denotes the ISA Standard G3 option with -20 to 70°C temperature option; /A4D00 is an option code.

VI. Why Choose Us

  • Professional channel supply, comprehensive model coverage across multiple brands of DCS cards and process automation spare parts
  • Strict quality inspection process ensuring reliable product quality
  • Professional engineering team providing technical support and selection consultation
  • Quick response, efficient logistics, orders accepted
  • Quality assurance, worry-free after-sales service

VII. FAQ

Q1: What is Yokogawa AAI143-S53/A4D00?

A: A Japan Yokogawa CENTUM VP FIO analog input module with 16 isolated channels for 4 to 20 mA current input.

Q2: What are the accuracy and update period of this module?

A: Accuracy ±16 μA, data update period 10 ms.

Q3: Can this module power 2-wire transmitters?

A: Yes, supply voltage ≥19.0 V at 20 mA with 25 mA output current limit; each channel can be set for 2-wire or 4-wire transmitter input.

Q4: How to confirm compatibility with my system?

A: Verify the original model AAI143 and suffix S53, and confirm the FCS model, terminal board/cable type, and whether HART function is required.