Siemens 3RV2011-1KA20 Motor Protection Circuit Breaker (S00 / CLASS 10 / 9-12.5 A / Spring Terminals)

The 3RV2011-1KA20 is a three-pole motor protection circuit breaker of the SIRIUS 3RV2 range in size S00, with a thermal overload release setting range of 9-12.5 A, a magnetic instantaneous short-circuit release at 163 A, CLASS 10 trip class, phase failure detection and isolator function; standard breaking capacity with Icu 100 kA at AC 400 V, rated operating voltage up to 690 V, spring (cage clamp) terminals and expandable auxiliary contacts, for overload and short-circuit protection of three-ph
online consultation

Product Details

I. Product Overview

The 3RV2011-1KA20 is a motor protection circuit breaker in size S00 of the SIRIUS 3RV2 range, providing overload and short-circuit protection for three-phase AC motors and combinable with contactors and other devices in sizes S00 and S0 to form motor starters. The breaker has a three-pole main circuit, a thermal overload release settable from 9 to 12.5 A with CLASS 10 trip class and phase failure detection; the short-circuit release is magnetic with an instantaneous setting of 163 A, and thermal overload protection to ANSI 49 is provided.

The main circuit rated operating voltage is 20 to 690 V (maximum 690 V in AC-3 and AC-3e), operating frequency 50 to 60 Hz, rated operating current 12.5 A and continuous current 12.5 A; rated AC-3 power is 3 kW at 230 V, 5.5 kW at 400 V, 7.5 kW at 500 V and 7.5 kW at 690 V, with a maximum switching frequency of 15 operations per hour. Breaking capacity: ultimate short-circuit current Icu is 100 kA at AC 240 V and 400 V, 42 kA at 500 V and 6 kA at 690 V; service short-circuit current Ics is 100 kA at 240 V and 400 V, 42 kA at 500 V and 4 kA at 690 V. For short-circuit protection of the main circuit in IT networks the recommended fuse ratings are gL/gG 63 A at 400 V, 50 A at 500 V and 40 A at 690 V.

The breaker has an isolator (disconnector) function and is suitable for safe shutdown, conforming to ISO 13849-1 device type 3 and IEC 61508-2 type A, with a B10 value of 5000, low-demand failure rate of 50 FIT and a maximum service life of 10 years, making it suitable for safety-related circuits; it does not provide safe enabling. Insulation voltage is 690 V (pollution degree 3, AC), rated impulse withstand voltage 6 kV, and the maximum permissible voltage for safe isolation between main and auxiliary circuits is 400 V in both earthed and unearthed networks.

Power loss at rated current in the thermal state is 9.25 W (3.1 W per pole). This model has no auxiliary contacts (0 NO + 0 NC) but accepts auxiliary switch modules; the auxiliary and control circuit voltage type is AC/DC. Switch position is indicated by the locking handle.

Connection uses spring (cage clamp) technology with terminals at both the top and bottom of the main circuit, accepting single or multi-strand conductors of 2× (0.5 to 4 mm²) and fine-strand conductors with or without ferrules of 2× (0.5 to 2.5 mm²), corresponding to AWG 2× (20 to 12), with a screwdriver of 3.0 × 0.5 mm (3 mm shank diameter).

Dimensions are 106 mm height × 45 mm width × 97 mm depth with a net weight of 345.6 g; the mounting position is any, fixed on 35 mm DIN rail to DIN EN 60715 by screw or snap-on mounting. Front and terminal protection is IP20, with finger-safe protection at the front; shock resistance is 25 g/11 ms to IEC 60068-2-27, mechanical life is 100 000 operations for main contacts and 100 000 for auxiliary contacts, and electrical life is 100 000 operations.

Environmental conditions: operating temperature -20 to +60°C (same range for temperature compensation), storage and transport temperature -50 to +80°C, relative air humidity 10% to 95%, and maximum installation altitude 2000 m.

Approvals and standards data: compliant with ATEX Directive 2014/34/EU under certificate DMT 02 ATEX F 001 with ignition protection Ex II (2) GD; UL file numbers E47705 (NLRV, NLRV7) and E156943 (NKJH, NKJH7); UL ratings are FLA 12.5 A at 480 V and 600 V, 0.5 hp at single-phase 110/120 V, 2 hp at 230 V, and 3 hp at three-phase 200/208 V and 220/230 V, 8 hp at 460/480 V and 10 hp at 575/600 V; RoHS compliant (10/01/2009).

II. Specifications

表格

Parameter Value
Model 3RV2011-1KA20
Product Type Designation 3RV2
Product Brand SIRIUS
Product Specification For motor protection
Size S00 (combinable with S00, S0)
Number of Poles (main circuit) 3
Thermal Overload Release Setting Range 9 to 12.5 A
Trip Class CLASS 10
Instantaneous Short-Circuit Release 163 A (magnetic)
Phase Failure Detection Yes
Ground Fault Detection No
Thermal Overload Protection (ANSI 49) Yes
Isolator (Disconnector) Function Yes
Auxiliary Contacts (this model) 0 NO + 0 NC (expandable)
Rated Operating Voltage 20 to 690 V
Max. Operating Voltage AC-3 / AC-3e 690 V
Operating Frequency 50 to 60 Hz
Rated Operating Current / Continuous Current 12.5 A / 12.5 A
Rated AC-3 Power (230 V / 400 V / 500 V / 690 V) 3 kW / 5.5 kW / 7.5 kW / 7.5 kW
Max. Switching Frequency (AC-3) 15 per hour
Icu (240 V / 400 V / 500 V / 690 V) 100 kA / 100 kA / 42 kA / 6 kA
Ics (240 V / 400 V / 500 V / 690 V) 100 kA / 100 kA / 42 kA / 4 kA
IT Network Main Circuit Fuse (400 V / 500 V / 690 V) gL/gG 63 A / 50 A / 40 A
Insulation Voltage (pollution degree 3, AC) 690 V
Rated Impulse Withstand Voltage 6 kV
Max. Voltage for Safe Isolation (main/auxiliary) 400 V
Power Loss (rated current, thermal / per pole) 9.25 W / 3.1 W
Dimensions (H × W × D) 106 × 45 × 97 mm
Net Weight 345.6 g
Mounting 35 mm DIN rail to DIN EN 60715, screw or snap-on, any position
Degree of Protection Front IP20; terminals IP20
Touch Protection Finger-safe at front (vertical touch)
Main Circuit Connection Spring (cage clamp), top and bottom
Conductor Capacity (single/multi-strand) 2× (0.5 to 4 mm²); AWG 2× (20 to 12)
Conductor Capacity (fine-strand, with/without ferrules) 2× (0.5 to 2.5 mm²)
Screwdriver 3.0 × 0.5 mm (3 mm shank)
Operating Temperature -20 to +60°C
Storage / Transport Temperature -50 to +80°C
Relative Air Humidity (operating) 10% to 95%
Max. Installation Altitude 2000 m
Shock Resistance 25 g / 11 ms (IEC 60068-2-27)
Mechanical Life (main / auxiliary contacts) 100 000 / 100 000 operations
Electrical Life 100 000 operations
Switch Position Indication Locking handle
Safety Application Safe shutdown: yes; safe enabling: no; ISO 13849-1 device type 3; IEC 61508-2 type A
B10 Value / Low-Demand Failure Rate 5000 / 50 FIT
ATEX 2014/34/EU, DMT 02 ATEX F 001, Ex II (2) GD
UL File Numbers E47705 (NLRV, NLRV7); E156943 (NKJH, NKJH7)
UL FLA (480 V / 600 V) 12.5 A / 12.5 A
UL Power (three-phase 460/480 V / 575/600 V) 8 hp / 10 hp

V. Model Description

The 3RV2011-1KA20 belongs to the SIRIUS 3RV2 range of motor protection circuit breakers in size S00 (45 mm wide). Family variants differ by thermal overload setting range and terminal type: the connection code in the suffix designates spring (cage clamp) or screw terminals, and the final digits designate whether transverse auxiliary contacts are included (this model has none). Selection should match the setting range to the motor rated current (9 to 12.5 A, about 5.5 kW at AC-3/400 V) and the terminal type to the panel wiring method.

VI. Why Choose Us

  • Professional channel supply covering Siemens SIRIUS low-voltage control and protection products
  • Strict quality inspection process ensuring reliable product quality
  • Professional engineering team providing technical support and selection consultation
  • Quick response, efficient logistics, orders accepted
  • Quality assurance, worry-free after-sales service

VII. FAQ

Q1: What is the setting range of this breaker?

A: Thermal overload release setting range 9 to 12.5 A, CLASS 10 trip class, with a magnetic instantaneous short-circuit release at 163 A.

Q2: What is the breaking capacity?

A: Ultimate short-circuit current Icu is 100 kA at AC 400 V, 42 kA at 500 V and 6 kA at 690 V.

Q3: What terminal type does it use?

A: Spring (cage clamp) terminals for the main circuit at both top and bottom, accepting 2× (0.5 to 4 mm²) single or multi-strand conductors.

Q4: Does it include auxiliary contacts?

A: This model has no built-in auxiliary contacts (0 NO + 0 NC) and can be expanded with auxiliary switch modules.