Company Culture  ꄲ  Electrical  ꄲ  Electrical Meters  ꄲ  Danfoss FC-302N250T5E20H2XGCXXXSXXXXAQBKCXXXXDX Variable Frequency Drive (250 kW / 380-500 V / Modbus TCP)
ꁆ ꁇ

Danfoss FC-302N250T5E20H2XGCXXXSXXXXAQBKCXXXXDX Variable Frequency Drive (250 kW / 380-500 V / Modbus TCP)

This unit is a VLT AutomationDrive FC 302 high-performance drive rated 250 kW at 400 V / 350 hp at 460 V with a three-phase 380-500 VAC supply and 110% normal overload for 60 s, delivering 480 A output current at 400 V; it uses the D4h IP20 chassis with an A2 (C3) RFI filter, graphical LCP panel and coated PCB, and includes Modbus TCP (MCA 122) plus a general purpose I/O card (MCB 101) for high-dynamic control of induction and permanent magnet motors.
online consultation

Product Details

  

I. Product Overview

This product is a drive of the Danfoss VLT AutomationDrive FC 302 range (FC 301 is the standard version, FC 302 the advanced high-dynamic version), used for variable speed control of three-phase induction motors and permanent magnet motors. This variant is rated 250 kW at 400 V, 350 hp at 460 V and 315 kW at 500 V, with the normal overload specification (110% current for 60 s) and a three-phase 380-500 VAC mains supply.

Output capability: at 400 V the continuous output current is 480 A, the 60-second intermittent overload current 528 A and the continuous apparent power 333 kVA; at 460 V the continuous output current is 443 A with 353 kVA continuous apparent power; at 500 V the continuous output current is 443 A. The chassis is D4h with IP20 protection (chassis mounting).

Configuration: this variant uses an H2 RFI filter (A2 class / C3 class), has no brake chopper, is fitted with the graphical local control panel LCP-102, has a coated PCB (for humid and corrosive-gas environments), has no mains options (no breaker, fuses, contactor or load-sharing terminals), standard cable entry, no heatsink air-flow duct, standard software and standard language pack.

Built-in options: A option is the Modbus TCP fieldbus card MCA 122; B option is the general purpose I/O card MCB 101 (adding digital and analog I/O); the C option and C1 option positions are empty (no MCO 305 motion control card, no MCB 113 extended relay card) with the standard controller; the D option position is empty (no MCB 107 24 V DC backup supply). Safe Torque Off (STO) with a dedicated safety input (terminal 37) is part of the standard drive configuration.

The range is intended for applications with high demands on dynamics, control accuracy and process integration, supporting a single-drive concept from ordinary variable speed duty to servo-like operation on any machine or production line, and can be extended with a wide range of fieldbus and functional options.

II. Specifications

表格

Parameter Value
Type Code FC-302N250T5E20H2XGCXXXSXXXXAQBKCXXXXDX
Product Range VLT AutomationDrive FC 302 (advanced)
Rated Power (400 V) 250 kW
Rated Power (460 V) 350 hp
Rated Power (500 V) 315 kW
Overload Normal overload 110% for 60 s
Mains Supply 3-phase 380-500 VAC
Output Current (400 V, continuous) 480 A
Output Current (400 V, 60 s overload) 528 A
Output Current (460/500 V, continuous) 443 A
Continuous Apparent Power (400 V) 333 kVA
Continuous Apparent Power (460 V) 353 kVA
Chassis D4h
Degree of Protection IP20 (chassis)
Dimensions (H × W × D) 1027 × 375 × 375 mm
Weight 125 kg
RFI Filter H2: A2 class (C3 class)
Brake Chopper None (X)
Local Control Panel Graphical LCP (LCP-102)
PCB Coating Coated (C)
Mains Options None (X)
Fieldbus (A option) Modbus TCP, MCA 122 (AQ)
Extension I/O (B option) General Purpose I/O MCB 101 (BK)
C Option / C1 Option None (CX / X)
Controller Software Standard controller (XX)
D Option None (DX)
Safety Function Safe Torque Off (STO) standard, terminal 37

V. Model Description

The 39-character type code reads as follows: FC-302 is the product group (VLT AutomationDrive FC 302); N250 is the 250 kW rating with N denoting normal overload; T is three-phase; 5 is the 380-500 VAC mains voltage; E20 is the IP20/chassis enclosure; H2 is the A2 class (C3) RFI filter; position 18 X means no brake chopper; G is the graphical LCP (LCP-102); C is coated PCB; position 21 X means no mains option; position 22 X is standard cable entry; position 23 X means no hardware adaptation; SXXX is the standard software version; X is the standard language pack; AQ is the A option Modbus TCP (MCA 122); BK is the B option general purpose I/O card (MCB 101); CX means no C option; position 35 X means no C1 option (MCB 113 extended relay card); XX is the standard controller; DX means no D option (MCB 107 24 V DC backup supply).

The range covers roughly 0.25 kW up to 710 kW and above with A, B, C, D and E frame sizes; selection starts from the motor current and overload requirement (110% normal or 150% high overload) to determine the power code, then the A/B/C/D options are chosen according to fieldbus, I/O, safety and braking needs.

VI. Why Choose Us

  • Professional channel supply covering Danfoss VLT drives and matching options
  • Strict quality inspection process ensuring reliable product quality
  • Professional engineering team providing technical support and selection consultation
  • Quick response, efficient logistics, orders accepted
  • Quality assurance, worry-free after-sales service

VII. FAQ

Q1: What are the power and voltage ratings of this model?

A: 250 kW at 400 V / 350 hp at 460 V / 315 kW at 500 V, with a three-phase 380-500 VAC supply and 110% normal overload for 60 s.

Q2: Which communication interface is included?

A: The Modbus TCP fieldbus card MCA 122 (A option) and the general purpose I/O card MCB 101 (B option).

Q3: What are the protection class and dimensions?

A: D4h chassis, IP20, 1027 × 375 × 375 mm, weight 125 kg.

Q4: Does it have a brake chopper?

A: This variant has no brake chopper (code X); a variant with the built-in brake chopper requires the letter B in position 18.