Emerson EV2000-4T0075G/0110P Universal Variable Speed Drive (7.5 kW Constant Torque / 11 kW Fan-Pump, 380 V Three-Phase)
I. Product Overview
This product is a three-phase 380 V class universal variable speed drive, type EV2000-4T0075G/0110P, in which one unit carries two load ratings: the G (constant torque) rating suits 7.5 kW motors at 17 A rated output current, and the P (fan-pump) rating suits 11 kW motors at 25 A. Input is three-phase 380–440 V, 50/60 Hz, and rated output voltage is 380 V.
The range uses flux vector PWM modulation with a 1:100 speed range, delivers 180% rated torque at 0.50 Hz and keeps steady-state speed accuracy within ±0.5% of rated synchronous speed. It provides automatic torque boost, four V/F curves, three acceleration/deceleration modes (linear, S-ramp, automatic), DC injection braking, jog, multi-step speed running, built-in PI closed-loop control, automatic energy saving, automatic voltage regulation (AVR), automatic current limiting and automatic carrier frequency adjustment. For equipment manufacturing applications it adds traverse operation, fixed-length control, droop control, tone adjustment, non-stop operation on power failure and bundling of command and reference channels.
The unit suits fan and pump (quadratic torque) loads as well as general machinery requiring constant torque output; overload capability is 150% of rated current for 1 minute and 200% for 0.5 second in G duty, and 110% for 1 minute and 150% for 1 second in P duty. Command sources include the operation panel, control terminals and serial port, while frequency references may be digital, analogue voltage, analogue current, pulse or serial; RS485 is standard, PROFIBUS can be reached through the TDS-PA01 adapter, and a remote keypad can be mounted up to 1000 m away.
II. Specifications
表格
| Parameter | Value |
|---|---|
| Type | EV2000-4T0075G/0110P |
| Product Name | Universal variable speed drive (three-phase 380 V class) |
| Rated Capacity | 11 kVA (G) / 17 kVA (P) |
| Rated Input Current | 20.5 A (G) / 26 A (P) |
| Rated Output Current | 17 A (G) / 25 A (P) |
| Motor Rating | 7.5 kW (G, constant torque) / 11 kW (P, fan-pump) |
| Input Voltage | Three-phase 380–440 V, 50/60 Hz |
| Permissible Voltage Range | 320–460 V; voltage imbalance <3%; frequency ±5% |
| Output Voltage | 380 V |
| Output Frequency Range | 0–650 Hz |
| Overload (G) | 150% rated current for 1 min; 200% for 0.5 s |
| Overload (P) | 110% rated current for 1 min; 150% for 1 s |
| Modulation | Flux vector PWM |
| Speed Range | 1:100 |
| Starting Torque | 180% rated torque at 0.50 Hz |
| Steady-state Speed Accuracy | ≤±0.5% rated synchronous speed |
| Frequency Accuracy | Digital ±0.01%; analogue ±0.2% |
| Frequency Resolution | Digital 0.01 Hz; analogue 0.1% of max. frequency |
| Torque Boost | Automatic; manual 0.1%–30.0% |
| V/F Curves | 4 (1 user-defined + 3 reduced-torque characteristics) |
| Acc/Dec | Linear, S-ramp and automatic; 4 acc/dec times, up to 60 hours |
| DC Braking | Start frequency 0.20–60.00 Hz; time 0–30.0 s; current G 0–100%, P 0–80% |
| Jog Frequency Range | 0.20–50.00 Hz |
| Pulse Output | 0–50 kHz |
| Analogue Output | 2 channels, 0/4–20 mA or 0/2–10 V selectable |
| Communication | RS485 (optional TDS-PA01 for PROFIBUS) |
| Degree of Protection | IP20 |
| Cooling | Forced air cooling with fan control |
| Mounting | Wall mounted |
| Efficiency | ≥93% (45 kW G and below) |
| Ambient Temperature | -10 … +40 °C (derating required at 40–50 °C) |
| Humidity | <95% RH, non-condensing |
| Vibration | <5.9 m/s² (0.6 g) |
| Operating Altitude | <1000 m (derating above) |
| Storage Temperature | -40 … +70 °C |
| Protection Functions | Phase loss (optional), over-current, over-voltage, under-voltage, over-heat, overload |
V. Model Description
EV2000-4T0075G/0110P is composed of series, voltage class, input phase, power and load type: EV2000 is the series code; 4 denotes the 380 V voltage class; T denotes three-phase input; 0075 is the 7.5 kW motor rating in G duty; 0110 is the 11 kW motor rating in P duty; G means constant torque duty and P means fan-pump duty. Because one unit carries both G and P ratings, the load type must be established first: constant torque loads are selected on the G rating of 17 A and fan/pump loads on the P rating of 25 A, and the P rating must not be treated as constant torque capability.
VI. Why Choose Us
- Professional channel supply covering common power ranges of universal drives
- Strict quality inspection process ensuring reliable product quality
- Professional engineering team providing technical support and selection verification
- Quick response, efficient logistics, orders accepted
- Quality assurance, worry-free after-sales service
VII. FAQ
Q1: Does this model drive a 7.5 kW or an 11 kW motor?
A: Both ratings apply: 7.5 kW (17 A) for constant torque duty and 11 kW (25 A) for fan-pump duty.
Q2: What is the input voltage range?
A: Three-phase 380–440 V, 50/60 Hz, with a permissible operating range of 320–460 V.
Q3: What is the overload capability?
A: In G duty 150% for 1 minute and 200% for 0.5 second; in P duty 110% for 1 minute and 150% for 1 second.
Q4: Does it support closed-loop control and communication?
A: The built-in PI provides closed-loop control; RS485 is standard and PROFIBUS is available through the TDS-PA01 adapter.