Emerson EV2000-4T0075G/0110P Universal Variable Speed Drive (7.5 kW Constant Torque / 11 kW Fan-Pump, 380 V Three-Phase)

This model is a three-phase 380 V class universal variable speed drive, type EV2000-4T0075G/0110P, with a dual rating: 7.5 kW constant torque (G) duty at 17 A rated output current and 11 kW fan-pump (P) duty at 25 A, using flux vector PWM control with 180% rated torque available at 0.50 Hz, for motor speed control, fan and pump energy saving and closed-loop process control.
online consultation

Product Details

I. Product Overview

This product is a three-phase 380 V class universal variable speed drive, type EV2000-4T0075G/0110P, in which one unit carries two load ratings: the G (constant torque) rating suits 7.5 kW motors at 17 A rated output current, and the P (fan-pump) rating suits 11 kW motors at 25 A. Input is three-phase 380–440 V, 50/60 Hz, and rated output voltage is 380 V.

The range uses flux vector PWM modulation with a 1:100 speed range, delivers 180% rated torque at 0.50 Hz and keeps steady-state speed accuracy within ±0.5% of rated synchronous speed. It provides automatic torque boost, four V/F curves, three acceleration/deceleration modes (linear, S-ramp, automatic), DC injection braking, jog, multi-step speed running, built-in PI closed-loop control, automatic energy saving, automatic voltage regulation (AVR), automatic current limiting and automatic carrier frequency adjustment. For equipment manufacturing applications it adds traverse operation, fixed-length control, droop control, tone adjustment, non-stop operation on power failure and bundling of command and reference channels.

The unit suits fan and pump (quadratic torque) loads as well as general machinery requiring constant torque output; overload capability is 150% of rated current for 1 minute and 200% for 0.5 second in G duty, and 110% for 1 minute and 150% for 1 second in P duty. Command sources include the operation panel, control terminals and serial port, while frequency references may be digital, analogue voltage, analogue current, pulse or serial; RS485 is standard, PROFIBUS can be reached through the TDS-PA01 adapter, and a remote keypad can be mounted up to 1000 m away.

II. Specifications

表格

Parameter Value
Type EV2000-4T0075G/0110P
Product Name Universal variable speed drive (three-phase 380 V class)
Rated Capacity 11 kVA (G) / 17 kVA (P)
Rated Input Current 20.5 A (G) / 26 A (P)
Rated Output Current 17 A (G) / 25 A (P)
Motor Rating 7.5 kW (G, constant torque) / 11 kW (P, fan-pump)
Input Voltage Three-phase 380–440 V, 50/60 Hz
Permissible Voltage Range 320–460 V; voltage imbalance <3%; frequency ±5%
Output Voltage 380 V
Output Frequency Range 0–650 Hz
Overload (G) 150% rated current for 1 min; 200% for 0.5 s
Overload (P) 110% rated current for 1 min; 150% for 1 s
Modulation Flux vector PWM
Speed Range 1:100
Starting Torque 180% rated torque at 0.50 Hz
Steady-state Speed Accuracy ≤±0.5% rated synchronous speed
Frequency Accuracy Digital ±0.01%; analogue ±0.2%
Frequency Resolution Digital 0.01 Hz; analogue 0.1% of max. frequency
Torque Boost Automatic; manual 0.1%–30.0%
V/F Curves 4 (1 user-defined + 3 reduced-torque characteristics)
Acc/Dec Linear, S-ramp and automatic; 4 acc/dec times, up to 60 hours
DC Braking Start frequency 0.20–60.00 Hz; time 0–30.0 s; current G 0–100%, P 0–80%
Jog Frequency Range 0.20–50.00 Hz
Pulse Output 0–50 kHz
Analogue Output 2 channels, 0/4–20 mA or 0/2–10 V selectable
Communication RS485 (optional TDS-PA01 for PROFIBUS)
Degree of Protection IP20
Cooling Forced air cooling with fan control
Mounting Wall mounted
Efficiency ≥93% (45 kW G and below)
Ambient Temperature -10 … +40 °C (derating required at 40–50 °C)
Humidity <95% RH, non-condensing
Vibration <5.9 m/s² (0.6 g)
Operating Altitude <1000 m (derating above)
Storage Temperature -40 … +70 °C
Protection Functions Phase loss (optional), over-current, over-voltage, under-voltage, over-heat, overload

V. Model Description

EV2000-4T0075G/0110P is composed of series, voltage class, input phase, power and load type: EV2000 is the series code; 4 denotes the 380 V voltage class; T denotes three-phase input; 0075 is the 7.5 kW motor rating in G duty; 0110 is the 11 kW motor rating in P duty; G means constant torque duty and P means fan-pump duty. Because one unit carries both G and P ratings, the load type must be established first: constant torque loads are selected on the G rating of 17 A and fan/pump loads on the P rating of 25 A, and the P rating must not be treated as constant torque capability.

VI. Why Choose Us

  • Professional channel supply covering common power ranges of universal drives
  • Strict quality inspection process ensuring reliable product quality
  • Professional engineering team providing technical support and selection verification
  • Quick response, efficient logistics, orders accepted
  • Quality assurance, worry-free after-sales service

VII. FAQ

Q1: Does this model drive a 7.5 kW or an 11 kW motor?

A: Both ratings apply: 7.5 kW (17 A) for constant torque duty and 11 kW (25 A) for fan-pump duty.

Q2: What is the input voltage range?

A: Three-phase 380–440 V, 50/60 Hz, with a permissible operating range of 320–460 V.

Q3: What is the overload capability?

A: In G duty 150% for 1 minute and 200% for 0.5 second; in P duty 110% for 1 minute and 150% for 1 second.

Q4: Does it support closed-loop control and communication?

A: The built-in PI provides closed-loop control; RS485 is standard and PROFIBUS is available through the TDS-PA01 adapter.