Emerson Rosemount MAS2600-G40-05-0/0P Tank Contents Level Transmitter (Item No. 615366)
I. Product Overview
This product is a tank contents level transmitter, type MAS2600-G40-05-0/0P, new and original, item number 615366. It consists of three parts - the pressure transducer, the amplifier and the interconnecting cable - and is a two-wire 4-20 mA transmitter. The transducer is a pressure-sensitive silicon micro strain gauge sensor mounted in a glass-to-metal seal, with a titanium housing and titanium diaphragm, fully welded without joints and without the need for gaskets, resistant to seawater, hydrocarbons and chemicals.
The transducer can be mounted inside or outside, on the top or the side of tanks, and is submersible (IP68); the amplifier box is made of polyester, rated IP56, and must be mounted outside the tank in a dry area such as the engine room. The product is intended for marine tank level and draft measurement, with a programmable amplifier covering 0.2-35 mH2O, four gauge ranges of 0-3.5, 0-7, 0-16 and 0-35 mH2O, each divided into 8 sub-ranges selected by the range select switch, and a reference accuracy of ±0.25% of span at 20 °C.
Supply voltage is 17-33 VDC and the maximum loop resistance is calculated as (U-17 V)/32 mA. A built-in Pt100 temperature sensor is available (giving a proper reading only on internally mounted types), and cables are available in a standard version (up to 80 °C) and a high-temperature version (up to 125 °C). The product is intrinsically safe (Ex ia) with Umax 33 V, Li 20 µH and Ci 10 nF, and carries approvals from the major classification societies.
II. Specifications
表格
| Parameter | Value |
|---|---|
| Type | MAS2600-G40-05-0/0P |
| Item No. | 615366 |
| Product Name | Tank contents level transmitter |
| Construction | Pressure transducer + amplifier + interconnecting cable |
| Output Signal | Two-wire 4-20 mA |
| Measuring Principle | Silicon micro strain gauge in glass-to-metal seal |
| Programmable Range | 0.2-35 mH2O |
| Gauge Ranges | 0-3.5 / 0-7 / 0-16 / 0-35 mH2O (each with 8 sub-ranges) |
| Absolute Ranges | 0-20.394 / 0-35.690 mH2O or 0.8-3.5 bar abs |
| Reference Accuracy | ±0.25% of span at 20 °C |
| Supply Voltage | 17-33 VDC |
| Max. Loop Resistance | (U-17 V)/32 mA |
| Housing Material | Titanium (housing and diaphragm), fully welded |
| Enclosure Rating | Transducer IP68; amplifier box IP56 |
| Operating Temperature | -40 … +85 °C (standard); -20 … +125 °C (high temperature) |
| Dimensions | Transducer ∅25 mm, height 193 mm |
| Weight | 0.3 kg |
| Temperature Sensor | Optional built-in Pt100 (internally mounted types only) |
| Cable Temperature | Standard 80 °C; high temperature 125 °C |
| Intrinsic Safety | Ex ia; Umax 33 V, Li 20 µH, Ci 10 nF |
| Approvals | Major classification societies |
V. Model Description
The type follows the official ordering structure in four segments: MAS 2600 is the series; the first segment is the type code, where G denotes a gauge transducer (the series also offers A absolute and H high-temperature gauge); the following segments are the range code, the temperature sensor and cable code, and the amplifier and PCB code separated by a slash. In this type the first segment is G, i.e. gauge; the official segment-by-segment table for the remaining parts (G40, 05, 0/0P) was not obtained and is therefore not interpreted here. Selection and replacement must be verified against the complete type and item number, as gauge and absolute versions, and standard and high-temperature versions, are not interchangeable.
VI. Why Choose Us
- Professional channel supply covering marine level and pressure instruments
- Strict quality inspection process ensuring reliable product quality
- Professional engineering team providing technical support and model verification
- Quick response, efficient logistics, orders accepted
- Quality assurance, worry-free after-sales service
VII. FAQ
Q1: What signal does this transmitter output?
A: Two-wire 4-20 mA.
Q2: What is the measuring range?
A: Programmable range 0.2-35 mH2O; the gauge version offers 0-3.5, 0-7, 0-16 and 0-35 mH2O, each with 8 sub-ranges.
Q3: What are the supply and load requirements?
A: 17-33 VDC supply, with maximum loop resistance calculated as (U-17 V)/32 mA.
Q4: What are the protection ratings of the transducer and amplifier box?
A: Transducer IP68 (submersible), amplifier box IP56 (to be mounted outside the tank in a dry area).