Products

넳 넲

Classification

Company Culture  ꄲ  Automation  ꄲ  Modules  ꄲ  Control Modules  ꄲ  Honeywell FC-SDI-1624 Safety Manager Digital Input Module
ꁆ ꁇ

Honeywell FC-SDI-1624 Safety Manager Digital Input Module

The Honeywell FC-SDI-1624 is a 24 V DC, 16-channel safe digital input (SDI) module for the Honeywell Safety Manager (SIS) system, acquiring field on/off signals for safety-critical monitoring.
online consultation

Product Details

1. Product Overview

FC-SDI-1624 is a safe digital input (SDI) module for the Honeywell Safety Manager (SMS) system (also used in Experion PKS C300/C500). Designed for safety instrumented systems (SIS), it has 16 channels at 24 V DC to acquire discrete on/off signals from emergency stop buttons, limit switches and pressure switches, converting them quickly and reliably into digital signals for the controller.

Built for safety-critical applications, it provides high integrity and fast response, working with Honeywell's QMR redundancy architecture to maintain process availability.

2. Specifications

表格

Item Specification
Manufacturer Honeywell
Model FC-SDI-1624
System Safety Manager (SMS / SIS) / Experion PKS C300/C500
Product type Safe digital input (SDI) module
Channels 16
Input type 24 V DC digital (discrete on/off)
Signal source E-stop buttons, limit switches, pressure switches
Application Safety-critical acquisition (SIS/ESD)
Safety rating SIS-certified (SIL per system config)
Redundancy Works with QMR quadruple redundancy
Operating temp. −20 to +60 °C
Mounting Safety Manager / C300 rack

5. Model Information

  • Model: FC-SDI-1624
  • Product description: Honeywell Safety Manager 24 V DC, 16-channel safe digital input module.
  • Model note: FC = Honeywell Safety Manager series prefix; SDI = Safe Digital Input; 1624 = 16-channel, 24 V DC config (also listed as FS-SDI-1624). Exact hardware version per the unit label. Please email us.
  • Series features:
    • 16-channel 24 V DC safe digital input
    • For SIS / ESD safety-critical applications
    • Acquires E-stop, limit and pressure-switch discrete signals
    • High integrity, fast response
    • Works with QMR quadruple redundancy
  • Related products in series: Other Safety Manager I/O (SAI analog input, SDO/SAO); rack, power supply, redundant controller
  • Matching products: Safety Manager rack, power supply, comms module, field terminal assembly (FTA)

6. Why Choose Us

  1. Exact model match: We verify FC-SDI-1624 as supplied.
  2. Authorized channel supply: Honeywell Safety Manager spares through regular channels.
  3. Selection support: We help confirm hardware version and system matching.
  4. Delivery & after-sales: Quotation, lead-time confirmation and order follow-up provided; for questions, please email us.

7. FAQ

Q1: What is FC-SDI-1624?

A: A 24 V DC, 16-channel safe digital input module for Honeywell Safety Manager (SIS).

Q2: What signals?

A: 24 V DC digital (on/off) from E-stop buttons, limit switches and pressure switches.

Q3: How many channels?

A: 16 channels.

Q4: Which system?

A: Honeywell Safety Manager (SMS) / Experion PKS C300/C500 safety instrumented system (SIS).

Q5: Is it the same as FS-SDI-1624?

A: Same module under different labeling; exact hardware version per the unit label.

Q6: Applications?

A: Safety-critical signal acquisition, such as emergency shutdown (ESD) and safety interlocks. Please email us to verify.