Bosch Rexroth RC28-14/30 BODAS Mobile Hydraulic Controller
I. Product Overview
The RC28-14/30 is a programmable central controller of the Bosch Rexroth BODAS series for complex mobile working machines. It uses a 32-bit TriCore microcontroller SAK-TC1797 at 180 MHz with 1 MB RAM, 4 MB Flash and 32 kB EEPROM, with programs downloaded to Flash memory.
The controller provides 75 input channels handling 0 to 10 V and 0 to 32 V voltages, 0 to 20 mA currents, 0 to 10 kHz frequencies and switching signals, plus 4 resistor inputs (10 to 2000 Ω) for direct connection of temperature sensors. On the output side it offers 28 pulse-width-modulated (PWM) proportional solenoid current outputs, 14 switched outputs and 5 analog outputs; solenoid currents are closed-loop controlled and independent of voltage and temperature. Four independent CAN bus interfaces handle vehicle communication.
The controller includes cable break and short circuit detection, output monitoring, a watchdog, central deactivation of all outputs and a two-channel stop function, with IP65 protection when the correct mating connectors are fitted, making it suitable for mobile applications with -40 to 85°C ambient temperatures, high vibration and strong electromagnetic interference.
II. Specifications
表格
| Parameter | Value |
|---|---|
| Model | RC28-14/30 |
| Series | BODAS RC series 30 |
| Product Type | Freely programmable mobile hydraulic controller (ECU) |
| Microcontroller | 32-bit TriCore SAK-TC1797 |
| Clock Frequency | 180 MHz |
| Memory | RAM 1 MB, Flash 4 MB, EEPROM 32 kB |
| Nominal Voltage | 12 V and 24 V |
| Permissible Supply Range | 8 to 32 V |
| Residual Ripple | Max. ±2 V (DIN 40839 part 1) |
| Current Consumption (standby) | 380 mA in 12 V system; 290 mA in 24 V system |
| Current Consumption (loaded) | Max. 40 A |
| External Fuse | Electronics max. 35 A power outputs |
| Total Inputs | 75 channels |
| Digital Inputs | 9 |
| Diagnostics-capable Digital Voltage Inputs | 32 |
| Analog Voltage Inputs | 0 to 10 V, 7 channels; 0 to 32 V, 2 channels |
| Analog Current Inputs | 0 to 20 mA, 10 channels (diagnostics-capable) |
| Resistor Inputs | 10 to 2000 Ω, 4 channels (e.g. temperature sensors) |
| Frequency Inputs | 10 total: DSM 5 channels (0 to 9 kHz), inductive 2 channels (0 to 10 kHz), active 3 channels (0 to 10 kHz) |
| PWM Proportional Solenoid Outputs | 28 channels: high side 0 to 2.5 A, 18 channels; low side 0 to 3.0 A, 8 channels; low side 0 to 4.1 A, 2 channels |
| PWM Pulsation Frequency | 0; 50 to 250 Hz (low side additionally 1000 Hz) |
| Digital Outputs | 14 channels: high side max. 2.2 A, 10 channels; max. 3.5 A, 4 channels (max. 5 A per group) |
| Analog Outputs | 5 channels: 4 to 20 mA (200 Ω burden) 1 channel; 0 to 90% Ubat (12 kΩ burden, typically 25% to 75%) 4 channels |
| Sensor Supplies | 5 V/150 mA, 5 V/250 mA and 10 V/1000 mA, three independent |
| Communication | 4 × CAN (CAN 2.0 B, ISO 11898) |
| Diagnostics | Cable break and short circuit detection; monitoring of analog inputs, proportional outputs and switched outputs |
| Safety Functions | Watchdog, hardware RAM supervision, Flash ECC, two-channel stop function, central deactivation of all outputs |
| EMC | 200 Vrms/m (ISO 11452-2), 100 Vrms/m (ISO 11452-5); ESD 8 kV out of service / 15 kV in service (ISO 10605) |
| Power Dissipation | Electronics 8.5 W at 32 V; output stages 60 W at 32 V |
| Operating Temperature | -40 to +85°C (case, mounting point on cooling surface) |
| Storage Temperature | -40 to +105°C (short-term passive) |
| Vibration Resistance | Broadband noise vibration per ISO 16750-3 |
| Shock Resistance | 400 m/s², 6 ms, all three axes, positive and negative |
| Degree of Protection | IP65 with assembled mating connector |
| Case Material | Upper shell diecast aluminum, base deep-drawing aluminum |
| Dimensions | 204.5 × 203 × 40.5 mm (L × W × H) |
| Mass | Approx. 1.0 kg |
| Mating Connectors | 1 × 96-pin, 1 × 58-pin |
| Programming | IEC 61131-3 (BODAS-design), C-API |
V. Model Description
RC28-14/30 code structure: RC denotes a BODAS controller; in 28-14, 28 is the number of proportional outputs and 14 the number of switched outputs; 30 denotes series 3, index 0. The series also includes RC20-10/30 and RC12-10/30, which have the same 75 input channels and differ in the number of proportional and switched outputs.
VI. Why Choose Us
- Professional channel supply, comprehensive model coverage across multiple brands of mobile hydraulic electronics and hydraulic components
- Strict quality inspection process ensuring reliable product quality
- Professional engineering team providing technical support and selection consultation
- Quick response, efficient logistics, orders accepted
- Quality assurance, worry-free after-sales service
VII. FAQ
Q1: What is the RC28-14/30?
A: A Bosch Rexroth BODAS series freely programmable mobile hydraulic controller for electro-hydraulic proportional control and machine function coordination on mobile machinery.
Q2: How many outputs does this controller have?
A: 28 PWM proportional solenoid outputs, 14 switched outputs and 5 analog outputs (including one 4 to 20 mA).
Q3: Does it require software to operate?
A: Yes. The controller contains no program and requires BODAS standard software or a project-specific application program, programmable via BODAS-design (IEC 61131-3) or the C-API.
Q4: How to confirm suitability for my machine?
A: Verify the original model RC28-14/30 and the 96-pin plus 58-pin connector arrangement, confirm 12 V or 24 V system supply, the required I/O count and CAN interfaces, and that the case mounting point has adequate cooling.