Products

넳 넲

Classification

Company Culture  ꄲ  Electrical  ꄲ  Electrical Meters  ꄲ  ABB Adam DYN-Info M12-5 Non-Contact Safety Sensor (Eden Dynamic / 2TLA020051R5100)
ꁆ ꁇ

ABB Adam DYN-Info M12-5 Non-Contact Safety Sensor (Eden Dynamic / 2TLA020051R5100)

The Adam DYN-Info M12-5 is a coded non-contact safety sensor of the Eden Dynamic range (Adam side) that pairs with an Eva coded unit to form a guard interlocking device for doors, hatches and position monitoring; 0-15 mm sensing range, DYNlink dynamic signal plus one information output, 24 VDC supply at 30 mA, safety rating PL e / Cat. 4 and SIL3 (PFHd 4.5×10⁻⁹), IP67 and IP69K, M12 5-pole male connector, and series connection of up to 30 devices.
online consultation

Product Details

I. Product Overview

The Adam DYN-Info M12-5 belongs to the Eden Dynamic range of coded non-contact safety sensors, consisting of Adam (the sensor unit) and Eva (the coded actuator) forming one set, used for interlocking of doors, hatches and guards as well as position control and sector detection, in combination with a Vital safety module or a Pluto safety PLC.

The sensor is a high level coded design: with an Eva Unique actuator it is high level coded to EN ISO 14119 (Type 4), and low level coded with an Eva general actuator. A single Eden reaches PL e without the periodic checks of ISO/TR 24119, and several Eden units and other safety device types may be connected in series, up to 30 devices in series while maintaining PL e.

For signals, this model uses the DYNlink dynamic signal and additionally provides one information output (non-failsafe, undelayed semiconductor output, maximum 15 mA); when in contact with Eva the information output is +24 VDC, useful for status indication and troubleshooting. Other models in the range are Adam DYN-Reset (with reset/indication function, 2TLA020051R5300) and Adam OSSD-Info (OSSD signal, 2TLA020051R5400).

For sensing, the rated operating distance is 0 to 15 mm (Sn 15 mm, hysteresis 1 to 2 mm), with an assured operating distance Sao of 10 mm and an assured release distance Sar of 25 mm; the recommended distance between Adam and Eva is 7 mm and the minimum distance between two Eden units is 100 mm. Proximity of metal can influence the sensing distance and is avoided with DA 1B distance plates; this model is supplied with 4 pcs of DA 1B distance plates and 4 pcs of DA 2B distance rings.

Timing: switch-on delay after power on is 2 s, switch-on delay when Eva enters the range is <100 ms, switch-off delay when Eva is missing is <30 ms and the risk time is <30 ms; maximum switching frequency is 1 Hz and transponder frequency 4 MHz.

The supply is 24 VDC (+15%/-45%) with 30 mA consumption at 24 VDC. The housing is PBT with epoxy moulding, yellow, with IP67 and IP69K protection (0.6 N·m torque at the M12 contact) and an M12 5-pole male connector. Operating and storage temperature are -40 to +70°C, humidity 35% to 85% (no icing, no condensation), and EMC complies with EN 60947-5-3.

Safety data: IEC/EN 61508 SIL3 (PFHd 4.5×10⁻⁹), EN 62061 SIL3, EN ISO 13849-1 PL e / Cat. 4 and EN ISO 14119 Type 4; conforms to EN ISO 12100, EN 60204-1, EN 60664-1 and EN 61000-6-2 among others, with CE, UL/cUL (E353291) and TÜV approval.

II. Specifications

表格

Parameter Value
Model Adam DYN-Info M12-5
Product ID 2TLA020051R5100
EAN 7350024480306
Product Type Coded non-contact safety sensor (Adam side)
Range Eden Dynamic
Signal Type DYNlink dynamic signal plus information output
Number of Outputs 1 non-failsafe, undelayed semiconductor output
Information Output Current Max. 15 mA (Adam DYN-Info)
Rated Control Supply Voltage 24 VDC (+15% / -45%)
Power Consumption 30 mA at 24 VDC
Rated Operating Distance Sn 15 mm
Sensing Range 0 to 15 mm (±2 mm), hysteresis 1 to 2 mm
Assured Operating Distance Sao 10 mm
Assured Release Distance Sar 25 mm
Recommended Adam-Eva Distance 7 mm
Minimum Distance Between Two Eden 100 mm
Switching Frequency Max. 1 Hz
Transponder Frequency 4 MHz
Switch-on Delay after Power On 2 s
Switch-on Delay, Eva in Range <100 ms
Switch-off Delay, Eva Missing <30 ms
Risk Time <30 ms
Safety Rating PL e / Cat. 4 (EN ISO 13849-1); SIL3 (IEC/EN 61508, EN 62061)
PFHd 4.5×10⁻⁹ per hour
Coding Level EN ISO 14119 Type 4 (high level coded with Eva Unique)
Series Connection Up to 30 devices while maintaining PL e
Connector M12 5-pole male
Degree of Protection IP67, IP69K (0.6 N·m at M12 contact)
Housing Material PBT, epoxy moulding
Colour Yellow
Operating Temperature -40 to +70°C
Storage Temperature -40 to +70°C
Humidity Range 35% to 85% (no icing, no condensation)
EMC EN 60947-5-3 (1999+A1:2005)
Dimensions Height 75.2 mm × width 30 mm
Net Weight 0.026 kg
Supplied Accessories 4 pcs DA 1B distance plates, 4 pcs DA 2B distance rings
Approvals CE; UL/cUL (E353291); TÜV (2TLC172134D0201)
Customs Tariff Number 8536508099

V. Model Description

This model is the Adam (sensor) side of an Eden Dynamic set: Adam denotes the sensor unit with connector, DYN denotes the DYNlink dynamic signal, Info denotes the information output (without the local reset button function), and M12-5 denotes the M12 5-pole male connector; the matching coded actuator is Eva (general code 2TLA020046R0800, Unique code configured per project). Related models in the range include Adam DYN-Reset M12-5 (2TLA020051R5300, with reset/indication output) and Adam OSSD-Info M12-5 (2TLA020051R5400, OSSD output); selection depends on the required signal type and whether local reset is needed.

VI. Why Choose Us

  • Professional channel supply covering ABB Jokab Safety sensors and safety control products
  • Strict quality inspection process ensuring reliable product quality
  • Professional engineering team providing technical support and selection consultation
  • Quick response, efficient logistics, orders accepted
  • Quality assurance, worry-free after-sales service

VII. FAQ

Q1: What does this sensor set include?

A: Eden consists of Adam (sensor) and Eva (coded actuator) as one set; this order code supplies Adam DYN-Info M12-5 with 4 pcs of DA 1B distance plates and 4 pcs of DA 2B distance rings, while the Eva actuator is configured separately.

Q2: What safety rating is achieved?

A: PL e / Cat. 4 to EN ISO 13849-1 and SIL3 to IEC 61508 and EN 62061, with PFHd 4.5×10⁻⁹ per hour and EN ISO 14119 Type 4.

Q3: Can several units be connected in series?

A: Yes, up to 30 Eden units in series while maintaining PL e.

Q4: What are the protection class and operating temperature?

A: IP67 and IP69K (0.6 N·m torque at the M12 contact), with an operating temperature range of -40 to +70°C.