ifm PM1689 Flush Pressure Sensor (Hygienic / -5 to 100 mbar / 4-20 mA + IO-Link)
I. Product Overview
The PM1689 is a flush pressure sensor for hygienic applications in the food and beverage industry, product designation PM-10BREA01-E-ZVG/US. The sensing element is a ceramic capacitive pressure measuring cell, and the wetted parts are stainless steel (1.4435 / 316L with surface Ra <0.4 μm and Rz = 4 μm), ceramics (99.9% Al₂O₃) and PTFE; combined with the flush diaphragm design it suits viscous media or liquids containing particles as well as liquid and gaseous media, allows flush mounting and withstands high-pressure cleaning with aggressive cleaning agents.
The measuring range is -0.005 to 0.1 bar (-5 to 100 mbar / -0.073 to 1.45 psi) and the measurement is relative (gauge) pressure; vacuum resistance is -1000 mbar, overload pressure 4000 mbar (400 kPa), minimum burst pressure 30000 mbar (3000 kPa), and the maximum permissible operating pressure for CRN applications is 4 bar. The media temperature range is -25 to 150°C.
The sensor provides two outputs: one analog output (4 to 20 mA, adjustable span, maximum load 700 Ω at Ub = 24 V, (Ub-9 V)/21.5 mA) and one digital output (IO-Link, configurable), with short-circuit and overload protection. The analog measuring start point is settable from -5 to 80 mbar and the end point from 15 to 100 mbar in 0.05 mbar steps, with a factory setting of ASP = 0.0 mbar; analog damping (dAA) is 0 to 4 s and the step response time is 30 ms in 2-wire and 7 ms in 3-wire operation.
Accuracy: repeatability <±0.1% (temperature fluctuation <10 K, turn down 1:1), characteristics deviation <±0.5% (linearity including hysteresis and repeatability, limit setting to DIN EN IEC 62828-1), linearity deviation <±0.25%, hysteresis deviation <±0.2% and long-term stability <±0.1% per year (turn down 1:1); the total deviation across the temperature range is ±0.15%/10 K from -25 to 15°C and ±0.2%/10 K from 80 to 150°C.
Communication is IO-Link: transfer type COM2 (38.4 kBaud), IO-Link revision 1.1 to IEC 61131-9, Smart Sensor Profile 3.1 (Measuring Sensor / Common I&D), no SIO mode, A-type master port required, minimum cycle time 3.2 ms and pressure resolution 0.02 mbar; cyclic process data comprises 16 bits of pressure plus 4 bits of device status, acyclic data supports application-specific tags and internal temperature, and the default DeviceID is 670.
Electrical and environmental data: operating voltage 18 to 30 VDC, minimum insulation resistance 100 MΩ (500 V DC), protection class III, reverse polarity protection and integrated watchdog; current consumption is 3.5 to 21.5 mA with a 1 s switch-on delay in 2-wire operation and <45 mA with a 0.5 s delay in 3-wire operation. Ambient temperature is -25 to 80°C and storage temperature -40 to 100°C, with housing protection IP67 / IP68 / IP69K; EMC to DIN EN 61000-6-2 and DIN EN 61000-6-3, shock resistance 50 g (11 ms, DIN EN 60068-2-27), vibration resistance 20 g (10 to 2000 Hz, DIN EN 60068-2-6) and MTTF of 323 years.
Mechanically, the cylindrical housing is stainless steel (1.4404 / 316L) with PBT, measuring Ø30.2 mm and 122 mm long at 337.4 g; the process connection is a G1 external thread sealing cone (-27 mm) with a sealing ring groove to DIN EN ISO 1179-2, tightening torque 20 N·m and switching cycles of 100 million; the electrical connection is one M12 connector (A-coded, 4 gold-plated contacts).
Approvals include 3-A, ACS, CE, CRN, cULus (UL file J022), EC 1935/2004, FCM CN, FCM JP, FDA, Hygienic Cleanable, IO-Link, NSF Reg31 and UKCA.
II. Specifications
表格
| Parameter | Value |
|---|---|
| Model | PM1689 |
| Product Designation | PM-10BREA01-E-ZVG/US |
| Product Type | Flush pressure sensor (hygienic) |
| Measuring Element | Ceramic capacitive pressure measuring cell |
| Pressure Type | Relative (gauge) pressure |
| Measuring Range | -0.005 to 0.1 bar / -5 to 100 mbar / -0.073 to 1.45 psi |
| Start Point Setting Range | -5 to 80 mbar |
| End Point Setting Range | 15 to 100 mbar |
| Setting Increment | 0.05 mbar |
| Factory Setting (ASP) | 0.0 mbar |
| Vacuum Resistance | -1000 mbar |
| Overload Pressure | 4000 mbar / 400 kPa |
| Minimum Burst Pressure | 30000 mbar / 3000 kPa |
| Max. Permissible Operating Pressure (CRN) | 4 bar |
| Media Temperature | -25 to 150°C |
| Media | Viscous or particle-containing liquids; liquids and gases |
| Flush Mounting | Yes |
| Operating Voltage | 18 to 30 V DC |
| Minimum Insulation Resistance | 100 MΩ (500 V DC) |
| Protection Class (electrical) | III |
| Reverse Polarity Protection / Watchdog | Yes / Yes |
| Current Consumption (2-wire / 3-wire) | 3.5 to 21.5 mA / <45 mA |
| Switch-on Delay (2-wire / 3-wire) | 1 s / 0.5 s |
| Number of Outputs | 2 |
| Output Signals | Analog; IO-Link (configurable) |
| Analog Current Output | 4 to 20 mA (adjustable span) |
| Max. Analog Load | 700 Ω (Ub = 24 V; (Ub-9 V)/21.5 mA) |
| Short-Circuit / Overload Protection | Yes / Yes |
| Analog Damping (dAA) | 0 to 4 s |
| Step Response Time (analog) | 2-wire: 30 ms; 3-wire: 7 ms |
| Repeatability | <±0.1% (temperature fluctuation <10 K, turn down 1:1) |
| Characteristics Deviation | <±0.5% (linearity incl. hysteresis and repeatability, DIN EN IEC 62828-1) |
| Linearity Deviation | <±0.25% (turn down 1:1) |
| Hysteresis Deviation | <±0.2% (turn down 1:1) |
| Long-term Stability | <±0.1% per year (turn down 1:1) |
| Total Temperature Deviation | -25 to 15°C: ±0.15%/10 K; 80 to 150°C: ±0.2%/10 K |
| Communication Interface | IO-Link |
| Transfer Type | COM2 (38.4 kBaud) |
| IO-Link Revision | 1.1 (IEC 61131-9) |
| Smart Sensor Profile | SSP 3.1 (Measuring Sensor / Common I&D) |
| SIO Mode | No |
| Master Port Type | A |
| Analog Process Data | 3 |
| Minimum Cycle Time | 3.2 ms |
| IO-Link Pressure Resolution | 0.02 mbar |
| Cyclic Process Data | Pressure 16 bits; device status 4 bits |
| Default DeviceID | 670 |
| Ambient Temperature | -25 to 80°C |
| Storage Temperature | -40 to 100°C |
| Housing Protection | IP67 / IP68 / IP69K |
| Shock Resistance | 50 g (11 ms, DIN EN 60068-2-27) |
| Vibration Resistance | 20 g (10 to 2000 Hz, DIN EN 60068-2-6) |
| MTTF | 323 years |
| Housing Material | Stainless steel (1.4404 / 316L); PBT |
| Wetted Materials | Ceramics (99.9% Al₂O₃); stainless steel (1.4435 / 316L, Ra <0.4 μm / Rz = 4 μm); PTFE |
| Dimensions | Ø30.2 mm, length 122 mm |
| Weight | 337.4 g |
| Process Connection | G1 external thread, sealing cone -27 mm |
| Sealing Ring Groove | DIN EN ISO 1179-2 |
| Tightening Torque | 20 N·m |
| Switching Cycles | 100 million |
| Electrical Connection | 1 × M12 connector, A-coded, 4 gold-plated contacts |
| Pack Unit | 1 piece |
| Approvals | 3-A, ACS, CE, CRN, cULus (J022), EC 1935/2004, FCM CN, FCM JP, FDA, Hygienic Cleanable, IO-Link, NSF Reg31, UKCA |
V. Model Description
The PM1689 belongs to the PM range of flush pressure sensors, product designation PM-10BREA01-E-ZVG/US: the range is characterised by a flush diaphragm and hygienic design, with measuring range differentiated by the suffix. Other models in the range cover different pressure ranges and process connection forms; selection should match the required range (this model -5 to 100 mbar), process connection (this model G1 external thread sealing cone) and output type (analog plus IO-Link) to the corresponding model and order code.
VI. Why Choose Us
- Professional channel supply covering ifm sensors and industrial automation spare parts
- Strict quality inspection process ensuring reliable product quality
- Professional engineering team providing technical support and selection consultation
- Quick response, efficient logistics, orders accepted
- Quality assurance, worry-free after-sales service
VII. FAQ
Q1: What is the measuring range?
A: -0.005 to 0.1 bar, i.e. -5 to 100 mbar, measured as relative (gauge) pressure.
Q2: Which output types are available?
A: One adjustable 4 to 20 mA analog output plus one IO-Link output (COM2, configurable), two outputs in total, with short-circuit and overload protection.
Q3: Which media and applications suit it?
A: The hygienic flush design suits viscous media, particle-containing liquids and liquids and gases in the food and beverage industry, withstands high-pressure cleaning with aggressive cleaning agents, and accepts media temperatures of -25 to 150°C.
Q4: What are the protection rating and connections?
A: Housing IP67 / IP68 / IP69K; process connection G1 external thread sealing cone, electrical connection M12 A-coded 4 gold-plated contacts.